<?xml version="1.0" encoding="UTF-8"?>
<rss xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:taxo="http://purl.org/rss/1.0/modules/taxonomy/" version="2.0">
  <channel>
    <title>topic Re: VISA:  (Hex 0xBFFF0015) but is responding to *IDN? in Instrument Control (GPIB, Serial, VISA, IVI)</title>
    <link>https://ni.lithium.com/t5/Instrument-Control-GPIB-Serial/VISA-Hex-0xBFFF0015-but-is-responding-to-IDN/m-p/806340#M32905</link>
    <description>No, you don't have to. The Agilent installer will probably place it in some default location and the LabVIEW wrapper will probably expect it there but you can place the dll anywhere you want and tell the LabVIEW functions where you have placed it. This is no different than any other LabVIEW VI with a Call Library function Node.</description>
    <pubDate>Mon, 10 Nov 2008 15:39:52 GMT</pubDate>
    <dc:creator>Dennis_Knutson</dc:creator>
    <dc:date>2008-11-10T15:39:52Z</dc:date>
    <item>
      <title>VISA:  (Hex 0xBFFF0015) but is responding to *IDN?</title>
      <link>https://ni.lithium.com/t5/Instrument-Control-GPIB-Serial/VISA-Hex-0xBFFF0015-but-is-responding-to-IDN/m-p/804720#M32859</link>
      <description>&lt;P&gt;I am using NI 488.2 GBIP controller&lt;/P&gt;&lt;P&gt;Whenever i try to commmunicate with the device it shows timeout error&lt;/P&gt;&lt;P&gt;While using Instrumentation and automation mode it responds to *IDN? but whenever I try any other command it again shows the same problem&lt;/P&gt;&lt;P&gt;When I try to open GBIP analyser it prompts GBIP+ analyser not connected&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Thu, 06 Nov 2008 14:06:57 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/Instrument-Control-GPIB-Serial/VISA-Hex-0xBFFF0015-but-is-responding-to-IDN/m-p/804720#M32859</guid>
      <dc:creator>sudhanshu</dc:creator>
      <dc:date>2008-11-06T14:06:57Z</dc:date>
    </item>
    <item>
      <title>Re: VISA:  (Hex 0xBFFF0015) but is responding to *IDN?</title>
      <link>https://ni.lithium.com/t5/Instrument-Control-GPIB-Serial/VISA-Hex-0xBFFF0015-but-is-responding-to-IDN/m-p/804774#M32862</link>
      <description>&lt;P&gt;You are not providing enough information. What is the make and model of the instrument? What is a command (other than *IDN?) that you have tried? I hope you are not expecting a response when you issue a command that does not end with '?'. &lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;Also, the analyzer function is only available for '+' type controllers - ie PCI-GPIB+. Use NI-Spy to monitor communication.&lt;/P&gt;</description>
      <pubDate>Thu, 06 Nov 2008 15:00:32 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/Instrument-Control-GPIB-Serial/VISA-Hex-0xBFFF0015-but-is-responding-to-IDN/m-p/804774#M32862</guid>
      <dc:creator>Dennis_Knutson</dc:creator>
      <dc:date>2008-11-06T15:00:32Z</dc:date>
    </item>
    <item>
      <title>Re: VISA:  (Hex 0xBFFF0015) but is responding to *IDN?</title>
      <link>https://ni.lithium.com/t5/Instrument-Control-GPIB-Serial/VISA-Hex-0xBFFF0015-but-is-responding-to-IDN/m-p/806229#M32892</link>
      <description>&lt;P&gt;The instrument connected to the sysem is Agilent 4156C semiconductor analyzer&lt;/P&gt;&lt;P&gt;I am not getting anything on NI spy as well.&lt;/P&gt;&lt;P&gt;I am not able to understand that analyzer mode is only for +type cards&lt;/P&gt;&lt;P&gt;Can zou let me know how can I get data from Agilent analyzer to labview using PCI-GBIP&lt;/P&gt;&lt;P&gt;I am new to GPIB so please bear with me&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Mon, 10 Nov 2008 13:26:13 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/Instrument-Control-GPIB-Serial/VISA-Hex-0xBFFF0015-but-is-responding-to-IDN/m-p/806229#M32892</guid>
      <dc:creator>sudhanshu</dc:creator>
      <dc:date>2008-11-10T13:26:13Z</dc:date>
    </item>
    <item>
      <title>Re: VISA:  (Hex 0xBFFF0015) but is responding to *IDN?</title>
      <link>https://ni.lithium.com/t5/Instrument-Control-GPIB-Serial/VISA-Hex-0xBFFF0015-but-is-responding-to-IDN/m-p/806231#M32893</link>
      <description>&lt;P&gt;other command whcih i am providing is &lt;/P&gt;&lt;P&gt;&lt;SPAN style="font-size: 12pt; font-family: Times"&gt;FORM:DATA
ASC; SOUR:FUNC&lt;SPAN&gt;&amp;nbsp; &lt;/SPAN&gt;SIN; SENS:DATA?&amp;nbsp; &lt;/SPAN&gt;&lt;/P&gt;&lt;P&gt;for whcih it shows timeout error&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Mon, 10 Nov 2008 13:28:20 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/Instrument-Control-GPIB-Serial/VISA-Hex-0xBFFF0015-but-is-responding-to-IDN/m-p/806231#M32893</guid>
      <dc:creator>sudhanshu</dc:creator>
      <dc:date>2008-11-10T13:28:20Z</dc:date>
    </item>
    <item>
      <title>Re: VISA:  (Hex 0xBFFF0015) but is responding to *IDN?</title>
      <link>https://ni.lithium.com/t5/Instrument-Control-GPIB-Serial/VISA-Hex-0xBFFF0015-but-is-responding-to-IDN/m-p/806290#M32899</link>
      <description>I've never used that instrument but I suspect it just isn't in a state that will return a measurement. You could try the &lt;A href="http://sine.ni.com/apps/utf8/niid_web_display.model_page?p_model_id=5035" target="_blank"&gt;driver&lt;/A&gt;.</description>
      <pubDate>Mon, 10 Nov 2008 14:51:19 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/Instrument-Control-GPIB-Serial/VISA-Hex-0xBFFF0015-but-is-responding-to-IDN/m-p/806290#M32899</guid>
      <dc:creator>Dennis_Knutson</dc:creator>
      <dc:date>2008-11-10T14:51:19Z</dc:date>
    </item>
    <item>
      <title>Re: VISA:  (Hex 0xBFFF0015) but is responding to *IDN?</title>
      <link>https://ni.lithium.com/t5/Instrument-Control-GPIB-Serial/VISA-Hex-0xBFFF0015-but-is-responding-to-IDN/m-p/806318#M32900</link>
      <description>&lt;P&gt;how&amp;nbsp;&amp;nbsp; to install the driver&lt;/P&gt;&lt;P&gt;i am quite new to this area please help&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Mon, 10 Nov 2008 15:20:43 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/Instrument-Control-GPIB-Serial/VISA-Hex-0xBFFF0015-but-is-responding-to-IDN/m-p/806318#M32900</guid>
      <dc:creator>sudhanshu</dc:creator>
      <dc:date>2008-11-10T15:20:43Z</dc:date>
    </item>
    <item>
      <title>Re: VISA:  (Hex 0xBFFF0015) but is responding to *IDN?</title>
      <link>https://ni.lithium.com/t5/Instrument-Control-GPIB-Serial/VISA-Hex-0xBFFF0015-but-is-responding-to-IDN/m-p/806320#M32901</link>
      <description>For the LabVIEW part, place the unzipped folder in your instr.lib folder. You'll also have to get the dll from Agilent.</description>
      <pubDate>Mon, 10 Nov 2008 15:23:02 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/Instrument-Control-GPIB-Serial/VISA-Hex-0xBFFF0015-but-is-responding-to-IDN/m-p/806320#M32901</guid>
      <dc:creator>Dennis_Knutson</dc:creator>
      <dc:date>2008-11-10T15:23:02Z</dc:date>
    </item>
    <item>
      <title>Re: VISA:  (Hex 0xBFFF0015) but is responding to *IDN?</title>
      <link>https://ni.lithium.com/t5/Instrument-Control-GPIB-Serial/VISA-Hex-0xBFFF0015-but-is-responding-to-IDN/m-p/806327#M32903</link>
      <description>do i need to place the dll in the same directory</description>
      <pubDate>Mon, 10 Nov 2008 15:28:36 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/Instrument-Control-GPIB-Serial/VISA-Hex-0xBFFF0015-but-is-responding-to-IDN/m-p/806327#M32903</guid>
      <dc:creator>sudhanshu</dc:creator>
      <dc:date>2008-11-10T15:28:36Z</dc:date>
    </item>
    <item>
      <title>Re: VISA:  (Hex 0xBFFF0015) but is responding to *IDN?</title>
      <link>https://ni.lithium.com/t5/Instrument-Control-GPIB-Serial/VISA-Hex-0xBFFF0015-but-is-responding-to-IDN/m-p/806340#M32905</link>
      <description>No, you don't have to. The Agilent installer will probably place it in some default location and the LabVIEW wrapper will probably expect it there but you can place the dll anywhere you want and tell the LabVIEW functions where you have placed it. This is no different than any other LabVIEW VI with a Call Library function Node.</description>
      <pubDate>Mon, 10 Nov 2008 15:39:52 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/Instrument-Control-GPIB-Serial/VISA-Hex-0xBFFF0015-but-is-responding-to-IDN/m-p/806340#M32905</guid>
      <dc:creator>Dennis_Knutson</dc:creator>
      <dc:date>2008-11-10T15:39:52Z</dc:date>
    </item>
  </channel>
</rss>
