    <title>topic Re: cannot save toolkit for previous version in LabVIEW</title>
    <link>https://ni.lithium.com/t5/LabVIEW/cannot-save-toolkit-for-previous-version/m-p/3790705#M1069293</link>
    <description>&lt;P&gt;10 years old&lt;/P&gt;</description>
    <pubDate>Tue, 08 May 2018 22:26:20 GMT</pubDate>
    <dc:creator>Gregory</dc:creator>
    <dc:date>2018-05-08T22:26:20Z</dc:date>
    <item>
      <title>cannot save toolkit for previous version</title>
      <link>https://ni.lithium.com/t5/LabVIEW/cannot-save-toolkit-for-previous-version/m-p/777943#M355890</link>
      <description>&lt;P&gt;i have two sub vis in my program that do nothing but set up daqmx tasks. these two vis however, will not save back to 8.5 from 8.6, it tells me i cant save toolkits to previous version.&lt;/P&gt;&lt;P&gt;BUT, these are not toolkit vis, they are standard labview vis from the measurement, daqmx pallette.&lt;/P&gt;&lt;P&gt;AND, i have other subvis that set up tasks the same way , and they converted backwards just fine.&lt;/P&gt;&lt;P&gt;i have attached the two subvis that wont save backwards. granted, i can rewrite them in 8.5, but it is weird that these 2 wont save back and others like them will.&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Tue, 16 Sep 2008 15:08:22 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/cannot-save-toolkit-for-previous-version/m-p/777943#M355890</guid>
      <dc:creator>EJW2003</dc:creator>
      <dc:date>2008-09-16T15:08:22Z</dc:date>
    </item>
    <item>
      <title>Re: cannot save toolkit for previous version</title>
      <link>https://ni.lithium.com/t5/LabVIEW/cannot-save-toolkit-for-previous-version/m-p/777990#M355911</link>
      <description>You should not backs-ave standard VIs that are found in the vi.lib directory. These VIs should be installed with LabVIEW based on the version that you're running. You should only back-save VIs that you have written.</description>
      <pubDate>Tue, 16 Sep 2008 15:51:40 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/cannot-save-toolkit-for-previous-version/m-p/777990#M355911</guid>
      <dc:creator>smercurio_fc</dc:creator>
      <dc:date>2008-09-16T15:51:40Z</dc:date>
    </item>
    <item>
      <title>Re: cannot save toolkit for previous version</title>
      <link>https://ni.lithium.com/t5/LabVIEW/cannot-save-toolkit-for-previous-version/m-p/778526#M356114</link>
      <description>&lt;P&gt;those 2 vis are ones that i have written. however, the code inside wont save back. and, like i said, i have 2 other vis just like these that configure daqmx as well, and they back save just fine.&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Wed, 17 Sep 2008 14:26:16 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/cannot-save-toolkit-for-previous-version/m-p/778526#M356114</guid>
      <dc:creator>EJW2003</dc:creator>
      <dc:date>2008-09-17T14:26:16Z</dc:date>
    </item>
    <item>
      <title>Re: cannot save toolkit for previous version</title>
      <link>https://ni.lithium.com/t5/LabVIEW/cannot-save-toolkit-for-previous-version/m-p/778883#M356265</link>
      <description>&lt;P&gt;Hello EJW2003,&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;As a quick fix you can copy and paste your block diagram into a new VI in LabVIEW 8.6 and then&amp;nbsp;I could save them back to LabVIEW 8.5.&amp;nbsp; I'll see if I can figure out what caused this behavior, but the copy/paste was a pretty quick fix.&amp;nbsp; Here are the two VI's for 8.5.&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;Cheers,&lt;/P&gt;</description>
      <pubDate>Wed, 17 Sep 2008 22:47:10 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/cannot-save-toolkit-for-previous-version/m-p/778883#M356265</guid>
      <dc:creator>Brooks_C</dc:creator>
      <dc:date>2008-09-17T22:47:10Z</dc:date>
    </item>
    <item>
      <title>Re: cannot save toolkit for previous version</title>
      <link>https://ni.lithium.com/t5/LabVIEW/cannot-save-toolkit-for-previous-version/m-p/779254#M356387</link>
      <description>Off-hand I'd guess the VI itself is probably corrupted.</description>
      <pubDate>Thu, 18 Sep 2008 14:11:08 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/cannot-save-toolkit-for-previous-version/m-p/779254#M356387</guid>
      <dc:creator>smercurio_fc</dc:creator>
      <dc:date>2008-09-18T14:11:08Z</dc:date>
    </item>
    <item>
      <title>Re: cannot save toolkit for previous version</title>
      <link>https://ni.lithium.com/t5/LabVIEW/cannot-save-toolkit-for-previous-version/m-p/779592#M356509</link>
      <description>&lt;P&gt;&lt;FONT size="3" color="#000000"&gt;Hello EJW2003,&lt;/FONT&gt;&lt;/P&gt;&lt;P&gt;&lt;FONT size="3" color="#000000"&gt;&amp;nbsp;&lt;/FONT&gt;&lt;/P&gt;&lt;P&gt;&lt;FONT size="3"&gt;&lt;FONT color="#000000"&gt;I agree with smercurio_fc, but I wanted to search around and make sure there weren't any known issues.&amp;nbsp; From what I've seen I think that this is an isolated incident, but if you find they you consistently have issues with saving back VI's I'd be more than happy to look into it.&amp;nbsp; If you do have further issues please provide steps to reproduce the behavior if at all possible.&lt;/FONT&gt;&lt;/FONT&gt;&lt;/P&gt;&lt;P&gt;&lt;FONT size="3" color="#000000"&gt;&amp;nbsp;&lt;/FONT&gt;&lt;/P&gt;&lt;P&gt;&lt;FONT size="3" color="#000000"&gt;Have a great day, and take care!&lt;/FONT&gt;&lt;/P&gt;&lt;P&gt;&lt;FONT size="3" color="#000000"&gt;&amp;nbsp;&lt;/FONT&gt;&lt;/P&gt;&lt;P&gt;&lt;FONT size="3" color="#000000"&gt;Cheers,&lt;/FONT&gt;&lt;/P&gt;</description>
      <pubDate>Thu, 18 Sep 2008 22:00:52 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/cannot-save-toolkit-for-previous-version/m-p/779592#M356509</guid>
      <dc:creator>Brooks_C</dc:creator>
      <dc:date>2008-09-18T22:00:52Z</dc:date>
    </item>
    <item>
      <title>cannot save toolkit for previous version</title>
      <link>https://ni.lithium.com/t5/LabVIEW/cannot-save-toolkit-for-previous-version/m-p/780552#M356888</link>
      <description>&lt;P&gt;That is because your VIs are created from some toolkit VI. For example, if you create a VI by the following steps:&lt;/P&gt;&lt;P&gt;1. Copy a toolkit VI (for example, DAQmx, digitial filter design toolkit, sound and vibration measurement toolkit) to your folder.&amp;nbsp;&lt;/P&gt;&lt;P&gt;2. Rename this VI.&lt;BR /&gt;3. Modify this VI and save it. &lt;/P&gt;&lt;P&gt;Now the new VI will not save to previous version. Your VIs are built based on DAQmx VI.&amp;nbsp; &lt;/P&gt;&lt;P&gt;There are some special information in a toolkit VI which prevent you from saving to previous version. &lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;The work around is as&amp;nbsp; Brooks suggested: copy the diagram of your VI into a new created empty VI, the new VI can be saved to previous version.&amp;nbsp; &lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;Hope this can helps.&amp;nbsp; &lt;/P&gt;&lt;DIV class="message-edit-history"&gt;&lt;SPAN class="edit-author"&gt;帖子被pine在&lt;/SPAN&gt;&lt;SPAN class="local-date"&gt; 09-22-2008&lt;/SPAN&gt;&lt;SPAN class="local-time"&gt; 05:05 PM&lt;/SPAN&gt;&lt;/DIV&gt;时编辑过了</description>
      <pubDate>Mon, 22 Sep 2008 08:05:13 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/cannot-save-toolkit-for-previous-version/m-p/780552#M356888</guid>
      <dc:creator>pine</dc:creator>
      <dc:date>2008-09-22T08:05:13Z</dc:date>
    </item>
    <item>
      <title>Re: cannot save toolkit for previous version</title>
      <link>https://ni.lithium.com/t5/LabVIEW/cannot-save-toolkit-for-previous-version/m-p/780737#M356970</link>
      <description>&lt;P&gt;actually there were 2 toolkits i had installed in trial version, although i did not use any vis from those toolkits in the creation of mine. i then uninstalled the toolkits after receiving the message the first time, even though i knew i didnt use them in it. i figured it was just some bug that was preventing me from saving back after having those toolkits installed. (state chart and report generation)&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Mon, 22 Sep 2008 13:37:07 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/cannot-save-toolkit-for-previous-version/m-p/780737#M356970</guid>
      <dc:creator>EJW2003</dc:creator>
      <dc:date>2008-09-22T13:37:07Z</dc:date>
    </item>
    <item>
      <title>Re: cannot save toolkit for previous version</title>
      <link>https://ni.lithium.com/t5/LabVIEW/cannot-save-toolkit-for-previous-version/m-p/780738#M356971</link>
      <description>&lt;P&gt;copying the block diagram from 8.6 and attempting to past into 8.5 was the first thing i tried. doing this resulted in an IMAGE, rather than actually block diagram code.&lt;/P&gt;&lt;P&gt;of course, as small as these vis are it would be simple enough to rewrite (as they are daq assistants converted to code, with some modifications), i figure the error i was getting was worth mentioning in case someone else runs into it with a much bigger vi!!!&lt;/P&gt;</description>
      <pubDate>Mon, 22 Sep 2008 13:39:56 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/cannot-save-toolkit-for-previous-version/m-p/780738#M356971</guid>
      <dc:creator>EJW2003</dc:creator>
      <dc:date>2008-09-22T13:39:56Z</dc:date>
    </item>
    <item>
      <title>Re: cannot save toolkit for previous version</title>
      <link>https://ni.lithium.com/t5/LabVIEW/cannot-save-toolkit-for-previous-version/m-p/3790655#M1069278</link>
      <description>&lt;P&gt;I'm having the same problem and my VI is pretty big. So it's not just you.&lt;/P&gt;</description>
      <pubDate>Tue, 08 May 2018 20:03:28 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/cannot-save-toolkit-for-previous-version/m-p/3790655#M1069278</guid>
      <dc:creator>trip@amti</dc:creator>
      <dc:date>2018-05-08T20:03:28Z</dc:date>
    </item>
    <item>
      <title>Re: cannot save toolkit for previous version</title>
      <link>https://ni.lithium.com/t5/LabVIEW/cannot-save-toolkit-for-previous-version/m-p/3790705#M1069293</link>
      <description>&lt;P&gt;10 years old&lt;/P&gt;</description>
      <pubDate>Tue, 08 May 2018 22:26:20 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/cannot-save-toolkit-for-previous-version/m-p/3790705#M1069293</guid>
      <dc:creator>Gregory</dc:creator>
      <dc:date>2018-05-08T22:26:20Z</dc:date>
    </item>
  </channel>
</rss>
