<?xml version="1.0" encoding="UTF-8"?>
<rss xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:taxo="http://purl.org/rss/1.0/modules/taxonomy/" version="2.0">
  <channel>
    <title>topic Re: Panel control references in LabVIEW</title>
    <link>https://ni.lithium.com/t5/LabVIEW/Panel-control-references/m-p/4252074#M1237276</link>
    <description>&lt;BLOCKQUOTE&gt;&lt;HR /&gt;&lt;a href="https://ni.lithium.com/t5/user/viewprofilepage/user-id/704494"&gt;@chrni47&lt;/a&gt;&amp;nbsp;wrote:&lt;BR /&gt;
&lt;P&gt;Thank You...&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;The ForLoop output terminal conditional?&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;How do you place that?&lt;/P&gt;
&lt;HR /&gt;&lt;/BLOCKQUOTE&gt;
&lt;P&gt;Right clicking on the tunnel and selecting “Conditional Tunnel” or similar in the menu. It’s in the same place where you select if the tunnel is auto-indexing or not.&lt;/P&gt;
&lt;P&gt;That is if you have a recent version of LabVIEW. Older versions (2015? or so) don’t have that.&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;And your post is an additional question and not a solution, so it would be nice if you could unmark your post as solution and mark the post from the previous poster as solution instead!&lt;/P&gt;</description>
    <pubDate>Sun, 28 Aug 2022 09:47:18 GMT</pubDate>
    <dc:creator>rolfk</dc:creator>
    <dc:date>2022-08-28T09:47:18Z</dc:date>
    <item>
      <title>Panel control references</title>
      <link>https://ni.lithium.com/t5/LabVIEW/Panel-control-references/m-p/4250485#M1236666</link>
      <description>&lt;P&gt;My question: if I use a property node to list the controls&amp;nbsp;References on a sub VI panel.&lt;BR /&gt;Is there any way to negate some of the controls so they do not appear in the list of references on that panel.&lt;BR /&gt;Without removing the control from the sub VI panel?&lt;/P&gt;</description>
      <pubDate>Sat, 20 Aug 2022 21:53:26 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/Panel-control-references/m-p/4250485#M1236666</guid>
      <dc:creator>chrni47</dc:creator>
      <dc:date>2022-08-20T21:53:26Z</dc:date>
    </item>
    <item>
      <title>Re: Panel control references</title>
      <link>https://ni.lithium.com/t5/LabVIEW/Panel-control-references/m-p/4250489#M1236667</link>
      <description>&lt;P&gt;When you use the Panel/Pane property "Controls[]", you get the refnum of all the controls contained in the referenced Panel or Pane, even invisible ones.&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;By "&lt;SPAN&gt;negate some of the controls so they do not appear in the list&lt;/SPAN&gt;", I assume you mean to filter out some controls from the list ?&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;You can use all the available Control properties to decide which ones to keep in the list or not, e.g. Class Name, Label.Text, Value (in conjonction with "Get Type Information") , Indicator, Disabled, Visible,&amp;nbsp;&lt;SPAN&gt;etc...&lt;/SPAN&gt;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;Here is an example to get all visible indicators:&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&lt;span class="lia-inline-image-display-wrapper lia-image-align-inline" image-alt="Filter Panel Control References.png" style="width: 400px;"&gt;&lt;img src="https://ip1.i.lithium.com/fa40d3908d2cd83638fb00bf4622ca2b5d16ce15/68747470733a2f2f6e692e6c69746869756d2e636f6d2f74352f696d6167652f736572766572706167652f696d6167652d69642f33303730373769433733423146464530464630344238362f696d6167652d73697a652f6d656469756d3f763d76322670783d343030" role="button" title="Filter Panel Control References.png" alt="Filter Panel Control References.png" /&gt;&lt;/span&gt;&lt;/P&gt;</description>
      <pubDate>Sat, 20 Aug 2022 22:37:27 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/Panel-control-references/m-p/4250489#M1236667</guid>
      <dc:creator>raphschru</dc:creator>
      <dc:date>2022-08-20T22:37:27Z</dc:date>
    </item>
    <item>
      <title>Re: Panel control references</title>
      <link>https://ni.lithium.com/t5/LabVIEW/Panel-control-references/m-p/4252047#M1237269</link>
      <description>&lt;P&gt;Thank You...&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;The ForLoop output terminal conditional?&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;How do you place that?&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;Chris&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Sat, 27 Aug 2022 23:53:04 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/Panel-control-references/m-p/4252047#M1237269</guid>
      <dc:creator>chrni47</dc:creator>
      <dc:date>2022-08-27T23:53:04Z</dc:date>
    </item>
    <item>
      <title>Re: Panel control references</title>
      <link>https://ni.lithium.com/t5/LabVIEW/Panel-control-references/m-p/4252074#M1237276</link>
      <description>&lt;BLOCKQUOTE&gt;&lt;HR /&gt;&lt;a href="https://ni.lithium.com/t5/user/viewprofilepage/user-id/704494"&gt;@chrni47&lt;/a&gt;&amp;nbsp;wrote:&lt;BR /&gt;
&lt;P&gt;Thank You...&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;The ForLoop output terminal conditional?&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;How do you place that?&lt;/P&gt;
&lt;HR /&gt;&lt;/BLOCKQUOTE&gt;
&lt;P&gt;Right clicking on the tunnel and selecting “Conditional Tunnel” or similar in the menu. It’s in the same place where you select if the tunnel is auto-indexing or not.&lt;/P&gt;
&lt;P&gt;That is if you have a recent version of LabVIEW. Older versions (2015? or so) don’t have that.&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;And your post is an additional question and not a solution, so it would be nice if you could unmark your post as solution and mark the post from the previous poster as solution instead!&lt;/P&gt;</description>
      <pubDate>Sun, 28 Aug 2022 09:47:18 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/Panel-control-references/m-p/4252074#M1237276</guid>
      <dc:creator>rolfk</dc:creator>
      <dc:date>2022-08-28T09:47:18Z</dc:date>
    </item>
    <item>
      <title>Re: Panel control references</title>
      <link>https://ni.lithium.com/t5/LabVIEW/Panel-control-references/m-p/4252081#M1237278</link>
      <description>&lt;P&gt;I will next time,,,&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;Thanks..&lt;/P&gt;
&lt;P&gt;Chris&lt;/P&gt;</description>
      <pubDate>Sun, 28 Aug 2022 11:51:44 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/Panel-control-references/m-p/4252081#M1237278</guid>
      <dc:creator>chrni47</dc:creator>
      <dc:date>2022-08-28T11:51:44Z</dc:date>
    </item>
    <item>
      <title>Re: Panel control references</title>
      <link>https://ni.lithium.com/t5/LabVIEW/Panel-control-references/m-p/4252158#M1237301</link>
      <description>&lt;BLOCKQUOTE&gt;&lt;a href="https://ni.lithium.com/t5/user/viewprofilepage/user-id/6528"&gt;@rolfk&lt;/a&gt;&amp;nbsp;wrote:&lt;BR /&gt;&lt;SPAN&gt;And your post is an additional question and not a solution, so it would be nice if you could unmark your post as solution and mark the post from the previous poster as solution instead!&lt;/SPAN&gt;&lt;HR /&gt;&lt;/BLOCKQUOTE&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;BLOCKQUOTE&gt;&lt;HR /&gt;&lt;a href="https://ni.lithium.com/t5/user/viewprofilepage/user-id/704494"&gt;@chrni47&lt;/a&gt;&amp;nbsp;wrote:&lt;BR /&gt;
&lt;P&gt;I will next time,,,&lt;/P&gt;
&lt;HR /&gt;&lt;/BLOCKQUOTE&gt;
&lt;P&gt;Kudo (your 1st!) for fixing that. Note the use of kudos to say thanks...&lt;/P&gt;</description>
      <pubDate>Mon, 29 Aug 2022 08:14:04 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/Panel-control-references/m-p/4252158#M1237301</guid>
      <dc:creator>wiebe@CARYA</dc:creator>
      <dc:date>2022-08-29T08:14:04Z</dc:date>
    </item>