    <title>topic Re: daq 6008 basic vi in LabVIEW</title>
    <link>https://ni.lithium.com/t5/LabVIEW/daq-6008-basic-vi/m-p/240166#M130862</link>
    <description>&lt;DIV&gt;Hi, &lt;/DIV&gt;
&lt;DIV&gt;You can use DAQ assistant from the functions palette. It is express vi that you can configure every thing needed for acquisition and read the acquired signal. &lt;/DIV&gt;
&lt;DIV&gt;After configuring the DAQ Assistant VI you can put wavewform chart and see the acquired signal on the front panel.&lt;/DIV&gt;
&lt;DIV&gt;&amp;nbsp;&lt;/DIV&gt;
&lt;DIV&gt;good luck&lt;/DIV&gt;
&lt;DIV&gt;&amp;nbsp;&lt;/DIV&gt;
&lt;DIV&gt;Tareq&lt;/DIV&gt;</description>
    <pubDate>Tue, 12 Jul 2005 12:32:10 GMT</pubDate>
    <dc:creator>Tareq</dc:creator>
    <dc:date>2005-07-12T12:32:10Z</dc:date>
    <item>
      <title>daq 6008 basic vi</title>
      <link>https://ni.lithium.com/t5/LabVIEW/daq-6008-basic-vi/m-p/240140#M130857</link>
      <description>I've bought a DAQ 6008 for using with LabView 7.1, Windows XP.&lt;BR /&gt;I'm trying to do a basic data acquisition VI so I can read an analog input. However, I'm having troubles working with the tasks.&lt;BR /&gt;Does anyone have a simple and ready to use VI for reading an analog input and plot it in a chart?&lt;BR /&gt;&lt;BR /&gt;Thank you,&lt;BR /&gt;Joao</description>
      <pubDate>Tue, 12 Jul 2005 11:47:37 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/daq-6008-basic-vi/m-p/240140#M130857</guid>
      <dc:creator>jpsimoes</dc:creator>
      <dc:date>2005-07-12T11:47:37Z</dc:date>
    </item>
    <item>
      <title>Re: daq 6008 basic vi</title>
      <link>https://ni.lithium.com/t5/LabVIEW/daq-6008-basic-vi/m-p/240166#M130862</link>
      <description>&lt;DIV&gt;Hi, &lt;/DIV&gt;
&lt;DIV&gt;You can use DAQ assistant from the functions palette. It is express vi that you can configure every thing needed for acquisition and read the acquired signal. &lt;/DIV&gt;
&lt;DIV&gt;After configuring the DAQ Assistant VI you can put wavewform chart and see the acquired signal on the front panel.&lt;/DIV&gt;
&lt;DIV&gt;&amp;nbsp;&lt;/DIV&gt;
&lt;DIV&gt;good luck&lt;/DIV&gt;
&lt;DIV&gt;&amp;nbsp;&lt;/DIV&gt;
&lt;DIV&gt;Tareq&lt;/DIV&gt;</description>
      <pubDate>Tue, 12 Jul 2005 12:32:10 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/daq-6008-basic-vi/m-p/240166#M130862</guid>
      <dc:creator>Tareq</dc:creator>
      <dc:date>2005-07-12T12:32:10Z</dc:date>
    </item>
    <item>
      <title>Re: daq 6008 basic vi</title>
      <link>https://ni.lithium.com/t5/LabVIEW/daq-6008-basic-vi/m-p/240237#M130892</link>
      <description>Well, the DAQ Assistant is not compatible with DAQmx Base which is used for the 6008. I don't use any of the USB cards but this same question has been posted numerous times and I know DAQmx Base ships with several examples. Search the forum for 6008 and you'll find posts that tell you where to find them exactly. You should also be open any of the regular DAQmx examples and look at them. Replace the regular DAQmx functions with the functions of the same name in DAQmx base.
&lt;DIV&gt;&lt;/DIV&gt;</description>
      <pubDate>Tue, 12 Jul 2005 13:51:22 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/daq-6008-basic-vi/m-p/240237#M130892</guid>
      <dc:creator>Dennis_Knutson</dc:creator>
      <dc:date>2005-07-12T13:51:22Z</dc:date>
    </item>
    <item>
      <title>Re: daq 6008 basic vi</title>
      <link>https://ni.lithium.com/t5/LabVIEW/daq-6008-basic-vi/m-p/240368#M130941</link>
      <description>&lt;DIV&gt;Hello,&lt;/DIV&gt;
&lt;DIV&gt;&amp;nbsp;&lt;/DIV&gt;
&lt;DIV&gt;&amp;nbsp;&lt;/DIV&gt;
&lt;DIV&gt;I'm trying to measure an analog input&amp;nbsp;signal with the enclosed VI file.&lt;/DIV&gt;
&lt;DIV&gt;However, when I read a square wave, there are zero values in the plot.&lt;/DIV&gt;
&lt;DIV&gt;I wonder if this is usual with this acquisition equipment (DAQ 6008) or if there's any problem with the program being tested.&lt;/DIV&gt;
&lt;DIV&gt;&amp;nbsp;&lt;/DIV&gt;
&lt;DIV&gt;Thanks in advanced,&lt;/DIV&gt;
&lt;DIV&gt;Joao&lt;/DIV&gt;</description>
      <pubDate>Tue, 12 Jul 2005 15:42:52 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/daq-6008-basic-vi/m-p/240368#M130941</guid>
      <dc:creator>jpsimoes</dc:creator>
      <dc:date>2005-07-12T15:42:52Z</dc:date>
    </item>
    <item>
      <title>Re: daq 6008 basic vi</title>
      <link>https://ni.lithium.com/t5/LabVIEW/daq-6008-basic-vi/m-p/253496#M136917</link>
      <description>&lt;P&gt;&lt;FONT size="2" color="#0033cc"&gt;Hello,&lt;/FONT&gt;&lt;/P&gt;
&lt;P data-unlink="true"&gt;&lt;FONT size="2" color="#0033cc"&gt;USB-6008 is now suppoted by NI-DAQmx. You need NI-DAQmx 7.5, which can be downloaded here : http://digital.ni.com/softlib.nsf/websearch/CF7ECCEA4C4CC7DE86257038004D88AE&amp;nbsp;&lt;/FONT&gt;&lt;/P&gt;
&lt;P&gt;&lt;FONT size="2" color="#0033cc"&gt;Regards,&lt;/FONT&gt;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;DIV&gt;&amp;nbsp;&lt;/DIV&gt;</description>
      <pubDate>Thu, 29 May 2025 18:26:50 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/daq-6008-basic-vi/m-p/253496#M136917</guid>
      <dc:creator>Isabelle</dc:creator>
      <dc:date>2025-05-29T18:26:50Z</dc:date>
    </item>
    <item>
      <title>Re: daq 6008 basic vi</title>
      <link>https://ni.lithium.com/t5/LabVIEW/daq-6008-basic-vi/m-p/254175#M137248</link>
      <description>&lt;DIV&gt;
&lt;DIV&gt;Hi...&lt;/DIV&gt;
&lt;DIV&gt;&amp;nbsp;&lt;/DIV&gt;
&lt;DIV&gt;I saw your Vi file.&lt;/DIV&gt;
&lt;DIV&gt;&amp;nbsp;&lt;/DIV&gt;
&lt;DIV&gt;Please try with this [beginnig left to right]:&lt;/DIV&gt;
&lt;DIV&gt;1. Delete the DAQmx Base Create Task&lt;/DIV&gt;
&lt;DIV&gt;2. Delete the DAQmx Base Create Virtual Channel.&lt;/DIV&gt;
&lt;DIV&gt;3. Delete the Input Terminal Configuration constant&lt;/DIV&gt;
&lt;DIV&gt;4. Delte the task connected in Physical Channel.&lt;/DIV&gt;
&lt;DIV&gt;&amp;nbsp;&lt;/DIV&gt;
&lt;DIV&gt;5. Make a task in NI-DAQ Base Configuration Utility.&lt;/DIV&gt;
&lt;DIV&gt;6. Create a task constant (type the task you made) and connect it to the "task/channel in" on the DAQmx Base Start&amp;nbsp;Task.&lt;/DIV&gt;
&lt;DIV&gt;&amp;nbsp;&lt;/DIV&gt;
&lt;DIV&gt;7.&amp;nbsp;Delete the DAQmx&amp;nbsp;Base Clear Task&lt;/DIV&gt;
&lt;DIV&gt;8. Connect the&amp;nbsp;Simple Error Handler VI to DAQmx&amp;nbsp;Base&amp;nbsp;Stop Task&amp;nbsp;directly.&lt;/DIV&gt;
&lt;DIV&gt;&amp;nbsp;&lt;/DIV&gt;
&lt;DIV&gt;9. I recommend begin with a time delay about 50, if it works... then decrement this value.&lt;/DIV&gt;
&lt;DIV&gt;&amp;nbsp;&lt;/DIV&gt;
&lt;DIV&gt;PD. Sorry about my english &lt;span class="lia-unicode-emoji" title=":face_with_tongue:"&gt;😛&lt;/span&gt; &lt;/DIV&gt;
&lt;DIV&gt;&amp;nbsp;&lt;/DIV&gt;
&lt;DIV&gt;
&lt;HR /&gt;
&lt;/DIV&gt;
&lt;DIV&gt;Hello,&lt;/DIV&gt;
&lt;DIV&gt;&amp;nbsp;&lt;/DIV&gt;
&lt;DIV&gt;&amp;nbsp;&lt;/DIV&gt;
&lt;DIV&gt;I'm trying to measure an analog input&amp;nbsp;signal with the enclosed VI file.&lt;/DIV&gt;
&lt;DIV&gt;However, when I read a square wave, there are zero values in the plot.&lt;/DIV&gt;
&lt;DIV&gt;I wonder if this is usual with this acquisition equipment (DAQ 6008) or if there's any problem with the program being tested.&lt;/DIV&gt;
&lt;DIV&gt;&amp;nbsp;&lt;/DIV&gt;
&lt;DIV&gt;Thanks in advanced,&lt;/DIV&gt;
&lt;DIV&gt;Joao&lt;/DIV&gt;&lt;/DIV&gt;</description>
      <pubDate>Fri, 12 Aug 2005 21:55:02 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/daq-6008-basic-vi/m-p/254175#M137248</guid>
      <dc:creator>Zicco</dc:creator>
      <dc:date>2005-08-12T21:55:02Z</dc:date>
    </item>
    <item>
      <title>Re: daq 6008 basic vi</title>
      <link>https://ni.lithium.com/t5/LabVIEW/daq-6008-basic-vi/m-p/254241#M137270</link>
      <description>Thank you for your help. The problem is solved!</description>
      <pubDate>Sat, 13 Aug 2005 09:27:20 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/daq-6008-basic-vi/m-p/254241#M137270</guid>