<?xml version="1.0" encoding="UTF-8"?>
<rss xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:taxo="http://purl.org/rss/1.0/modules/taxonomy/" version="2.0">
  <channel>
    <title>topic Re: clone vi in LabVIEW</title>
    <link>https://ni.lithium.com/t5/LabVIEW/clone-vi/m-p/802709#M366151</link>
    <description>&lt;IMG src="http://forums.ni.com/ni/attachments/ni/170/366150/1/clone.PNG" border="0" /&gt;</description>
    <pubDate>Mon, 03 Nov 2008 16:16:05 GMT</pubDate>
    <dc:creator>lavalava</dc:creator>
    <dc:date>2008-11-03T16:16:05Z</dc:date>
    <item>
      <title>clone vi</title>
      <link>https://ni.lithium.com/t5/LabVIEW/clone-vi/m-p/802707#M366150</link>
      <description>&lt;P&gt;Guys,&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;Quick question, how do you clone a VI?&amp;nbsp; I just download an example but I'm not sure how this guy did it...&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Mon, 03 Nov 2008 16:15:29 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/clone-vi/m-p/802707#M366150</guid>
      <dc:creator>lavalava</dc:creator>
      <dc:date>2008-11-03T16:15:29Z</dc:date>
    </item>
    <item>
      <title>Re: clone vi</title>
      <link>https://ni.lithium.com/t5/LabVIEW/clone-vi/m-p/802709#M366151</link>
      <description>&lt;IMG src="http://forums.ni.com/ni/attachments/ni/170/366150/1/clone.PNG" border="0" /&gt;</description>
      <pubDate>Mon, 03 Nov 2008 16:16:05 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/clone-vi/m-p/802709#M366151</guid>
      <dc:creator>lavalava</dc:creator>
      <dc:date>2008-11-03T16:16:05Z</dc:date>
    </item>
    <item>
      <title>Re: clone vi</title>
      <link>https://ni.lithium.com/t5/LabVIEW/clone-vi/m-p/802711#M366153</link>
      <description>I've noticed that if I hit ctrl+m, it loses all clone mode but how do I get back to clone mode or vice versa?</description>
      <pubDate>Mon, 03 Nov 2008 16:17:18 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/clone-vi/m-p/802711#M366153</guid>
      <dc:creator>lavalava</dc:creator>
      <dc:date>2008-11-03T16:17:18Z</dc:date>
    </item>
    <item>
      <title>Re: clone vi</title>
      <link>https://ni.lithium.com/t5/LabVIEW/clone-vi/m-p/802713#M366154</link>
      <description>&lt;P&gt;VI properties &amp;gt;&amp;gt;&amp;gt; Execution&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;Set VI as re-entrant.&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;Ben&lt;/P&gt;</description>
      <pubDate>Mon, 03 Nov 2008 16:18:37 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/clone-vi/m-p/802713#M366154</guid>
      <dc:creator>Ben</dc:creator>
      <dc:date>2008-11-03T16:18:37Z</dc:date>
    </item>
    <item>
      <title>Re: clone vi</title>
      <link>https://ni.lithium.com/t5/LabVIEW/clone-vi/m-p/802719#M366155</link>
      <description>the file was set as "re-entrant" but if I drag and drop this file into another VI, it doesn't show up as clone.&amp;nbsp; How should I go about doing it?&amp;nbsp; thanks</description>
      <pubDate>Mon, 03 Nov 2008 16:25:29 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/clone-vi/m-p/802719#M366155</guid>
      <dc:creator>lavalava</dc:creator>
      <dc:date>2008-11-03T16:25:29Z</dc:date>
    </item>
    <item>
      <title>Re: clone vi</title>
      <link>https://ni.lithium.com/t5/LabVIEW/clone-vi/m-p/802723#M366156</link>
      <description>&lt;P&gt;&lt;A href="https://www.ni.com/docs/en-US/bundle/labview/page/reentrancy-allowing-simultaneous-calls-to-the-same-subvi.html#d16789e434" target="_blank" rel="noopener"&gt;The relevant LabVIEW help entry&lt;/A&gt;.&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P data-unlink="true"&gt;A description of the new feature. (When it was introduced in LabVIEW 8.0)&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;ctrl+M switches between run mode and edit mode, that's why things change.&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&lt;A href="http://forums.ni.com/ni/board/message?board.id=170&amp;amp;message.id=206926&amp;amp;requireLogin=False" target="_blank" rel="noopener"&gt;An earlier discussion&lt;/A&gt;.&lt;/P&gt;</description>
      <pubDate>Fri, 23 May 2025 17:21:24 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/clone-vi/m-p/802723#M366156</guid>
      <dc:creator>altenbach</dc:creator>
      <dc:date>2025-05-23T17:21:24Z</dc:date>
    </item>
    <item>
      <title>Re: clone vi</title>
      <link>https://ni.lithium.com/t5/LabVIEW/clone-vi/m-p/802730#M366158</link>
      <description>i've read those threads before I post this one, all I want to do is create a clone.&amp;nbsp; After I set my VI to re-entrant, I drag and drop this file into another file and it still would not show up as a clone.&amp;nbsp; How can I insert a re-entrant file as a clone?</description>
      <pubDate>Mon, 03 Nov 2008 16:40:56 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/clone-vi/m-p/802730#M366158</guid>
      <dc:creator>lavalava</dc:creator>
      <dc:date>2008-11-03T16:40:56Z</dc:date>
    </item>
    <item>
      <title>Re: clone vi</title>
      <link>https://ni.lithium.com/t5/LabVIEW/clone-vi/m-p/802741#M366161</link>
      <description>ok I got it thanks guys</description>
      <pubDate>Mon, 03 Nov 2008 16:51:03 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/clone-vi/m-p/802741#M366161</guid>
      <dc:creator>lavalava</dc:creator>
      <dc:date>2008-11-03T16:51:03Z</dc:date>
    </item>
    <item>
      <title>Re: clone vi</title>
      <link>https://ni.lithium.com/t5/LabVIEW/clone-vi/m-p/1829589#M626471</link>
      <description>&lt;P&gt;I have a strange thing happening that is because I have a cloned VI on my block diagram. After using CTRL-M to disable the cloning and getting a non-rentrant VI, I then save the non-reentrant VI in a folder so that I can access the VI. And when I open the saved VI it is in the non-reentrant mode!&amp;nbsp; However when I go back into the original VI that uses this cloned VI and replace the cloned VI with the non-cloned VI and then open it up I get the expected results where I can actually change the code in this VI. I have actually gone into the replaced reentrant version of the original cloned VI on the block diagram and then replaced the VI witht the saved non-reentrant version of the VI and changed the code in the VI and then saved it again.&amp;nbsp; Then I reopened the VI and looked the block diagram and the thing was still in the non-reentrant mode. However, When I saved the main VI the non-reentrant VI again became cloned as a reentrant version!&amp;nbsp; This seems to me to be really strange and I am at a loss to reason this out!&amp;nbsp; Can anyone explain this behavior?&lt;/P&gt;</description>
      <pubDate>Sat, 07 Jan 2012 19:08:51 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/clone-vi/m-p/1829589#M626471</guid>
      <dc:creator>cuthbert</dc:creator>
      <dc:date>2012-01-07T19:08:51Z</dc:date>
    </item>
    <item>
      <title>Re: clone vi</title>
      <link>https://ni.lithium.com/t5/LabVIEW/clone-vi/m-p/1829603#M626475</link>
      <description>&lt;P&gt;You are confusing terminology.&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;CTRL-M doesn't change a VI from reentrant to non-reentrant or enable/disable cloning.&amp;nbsp; You don't&amp;nbsp;"enable/disable" cloning.&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;Reentrancy is&amp;nbsp;a property defined under the File / VI properties/ Execution menu.&amp;nbsp; Ctrl-M changes the appearance of a VI from edit mode (what you normally see) to run mode (what you see if the VI is running.)&amp;nbsp; It will also allow a copy of a reentrant VI that is open (a "Clone") to open up the real, original copy of the VI so you can do editing on it.&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;A VI that is non-reentrant means there is only ever a single copy of the VI that is running at any given time.&amp;nbsp; If you try to call a non-reentrant VI from multiple places at the same time, each subVI instance has to wait until the other subVI instances have stopped using it.&amp;nbsp; With a reentrant VI, a copy of the VI is made when it is called (the "clone").&amp;nbsp; That means more than one copy of the same subVI can run at the same time, each with its own memory space.&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Sat, 07 Jan 2012 20:06:54 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/clone-vi/m-p/1829603#M626475</guid>
      <dc:creator>RavensFan</dc:creator>
      <dc:date>2012-01-07T20:06:54Z</dc:date>
    </item>
    <item>
      <title>Re: clone vi</title>
      <link>https://ni.lithium.com/t5/LabVIEW/clone-vi/m-p/3313943#M970536</link>
      <description>&lt;P&gt;Can you elaborate for the 2015 software how to change from reentrant back to a normal vi? &amp;nbsp;I looked under File&amp;gt;VI Properties and didn't see execution under this. &amp;nbsp;I would like to not have any cloned sub vi's and be able to do my editing as normal.&lt;/P&gt;&lt;P&gt;Thanks!!&lt;/P&gt;</description>
      <pubDate>Fri, 24 Jun 2016 20:33:44 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/clone-vi/m-p/3313943#M970536</guid>
      <dc:creator>ncm</dc:creator>
      <dc:date>2016-06-24T20:33:44Z</dc:date>
    </item>
    <item>
      <title>Re: clone vi</title>
      <link>https://ni.lithium.com/t5/LabVIEW/clone-vi/m-p/3313946#M970537</link>
      <description>&lt;BLOCKQUOTE&gt;&lt;HR /&gt;&lt;a href="https://ni.lithium.com/t5/user/viewprofilepage/user-id/257514"&gt;@ncm&lt;/a&gt; wrote:&lt;BR /&gt;&lt;P&gt;Can you elaborate for the 2015 software how to change from reentrant back to a normal vi? &amp;nbsp;I looked under File&amp;gt;VI Properties and didn't see execution under this. &amp;nbsp;I would like to not have any cloned sub vi's and be able to do my editing as normal.&lt;/P&gt;&lt;P&gt;Thanks!!&lt;/P&gt;&lt;HR /&gt;&lt;/BLOCKQUOTE&gt;&lt;P&gt;You should open it from the project manager.&amp;nbsp; Opening it from the block diagram opens up that cloned instance.&amp;nbsp; I assume this is so that when you are debugging you can have any/all of the instances open and can see them all working at the same time.&lt;/P&gt;</description>
      <pubDate>Fri, 24 Jun 2016 20:41:29 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/clone-vi/m-p/3313946#M970537</guid>
      <dc:creator>billko</dc:creator>
      <dc:date>2016-06-24T20:41:29Z</dc:date>
    </item>
    <item>
      <title>Re: clone vi</title>
      <link>https://ni.lithium.com/t5/LabVIEW/clone-vi/m-p/3313969#M970548</link>
      <description>&lt;BLOCKQUOTE&gt;&lt;HR /&gt;&lt;a href="https://ni.lithium.com/t5/user/viewprofilepage/user-id/257514"&gt;@ncm&lt;/a&gt; wrote:&lt;BR /&gt;&lt;P&gt;I would like to not have any cloned sub vi's and be able to do my editing as normal.&lt;/P&gt;&lt;HR /&gt;&lt;/BLOCKQUOTE&gt;&lt;P&gt;Just press ctrl+m on the clone and it will open the master for editing&lt;/P&gt;&lt;BLOCKQUOTE&gt;&lt;HR /&gt;&lt;a href="https://ni.lithium.com/t5/user/viewprofilepage/user-id/257514"&gt;@ncm&lt;/a&gt; wrote:&lt;BR /&gt;&lt;P&gt;Can you elaborate for the 2015 software how to change from reentrant back to a normal vi? &amp;nbsp;I looked under File&amp;gt;VI Properties and didn't see execution under this.&lt;/P&gt;&lt;HR /&gt;&lt;/BLOCKQUOTE&gt;&lt;P&gt;You have to do it on the master. VI properties are greyed out on the clone, so just press ctrl+m first, then change the settings.&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;&lt;IMG src="https://ni.lithium.com/ni/attachments/ni/170/970548/1/reent.png" border="0" alt="" title="" /&gt;&lt;/P&gt;</description>
      <pubDate>Fri, 24 Jun 2016 21:59:53 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/clone-vi/m-p/3313969#M970548</guid>
      <dc:creator>altenbach</dc:creator>
      <dc:date>2016-06-24T21:59:53Z</dc:date>
    </item>
    <item>
      <title>Re: clone vi</title>
      <link>https://ni.lithium.com/t5/LabVIEW/clone-vi/m-p/3314478#M970768</link>
      <description>&lt;P&gt;Thanks, altenbach!!!! &amp;nbsp;That is exactly what I needed, much appreciated!&amp;nbsp;&lt;img id="smileyvery-happy" class="emoticon emoticon-smileyvery-happy" src="https://ni.lithium.com/i/smilies/16x16_smiley-very-happy.gif" alt="Smiley Very Happy" title="Smiley Very Happy" /&gt;&lt;/P&gt;</description>
      <pubDate>Mon, 27 Jun 2016 14:52:26 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/clone-vi/m-p/3314478#M970768</guid>
      <dc:creator>ncm</dc:creator>
      <dc:date>2016-06-27T14:52:26Z</dc:date>
    </item>
  </channel>
</rss>
