<?xml version="1.0" encoding="UTF-8"?>
<rss xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:taxo="http://purl.org/rss/1.0/modules/taxonomy/" version="2.0">
  <channel>
    <title>topic Help Using Labview to control Kikusui power supply with a PIA4850 controller in LabVIEW</title>
    <link>https://ni.lithium.com/t5/LabVIEW/Help-Using-Labview-to-control-Kikusui-power-supply-with-a/m-p/1066689#M473003</link>
    <description>&lt;P style="margin: 0in 0in 0pt" class="MsoNormal"&gt;&lt;FONT face="Times New Roman" size="3" color="#000000"&gt;HI I need some help using Labview to control 4 Kikusui power supplies. We have a PIA4850 Kikusui power supply controller. I can use the visa test panel and see the PIA4850 but can see any of the power supplies. I have very limited use of Labview and only wrote a couple programs using GPIB. The PIA4850 is a USB controller and can control up to 32 PS. I can get it to work with a Excel demo software that came with the controllers so I know that it is working. Any help will be appreciated. I am using LabView 8.2 and have updated to the Ni-DAQ 9.0. I have a program that I need to incorporate the PIA4850 into once I figure out how to operate it. Thanks in advance.&lt;/FONT&gt;&lt;/P&gt;</description>
    <pubDate>Fri, 05 Feb 2010 01:44:05 GMT</pubDate>
    <dc:creator>antique</dc:creator>
    <dc:date>2010-02-05T01:44:05Z</dc:date>
    <item>
      <title>Help Using Labview to control Kikusui power supply with a PIA4850 controller</title>
      <link>https://ni.lithium.com/t5/LabVIEW/Help-Using-Labview-to-control-Kikusui-power-supply-with-a/m-p/1066689#M473003</link>
      <description>&lt;P style="margin: 0in 0in 0pt" class="MsoNormal"&gt;&lt;FONT face="Times New Roman" size="3" color="#000000"&gt;HI I need some help using Labview to control 4 Kikusui power supplies. We have a PIA4850 Kikusui power supply controller. I can use the visa test panel and see the PIA4850 but can see any of the power supplies. I have very limited use of Labview and only wrote a couple programs using GPIB. The PIA4850 is a USB controller and can control up to 32 PS. I can get it to work with a Excel demo software that came with the controllers so I know that it is working. Any help will be appreciated. I am using LabView 8.2 and have updated to the Ni-DAQ 9.0. I have a program that I need to incorporate the PIA4850 into once I figure out how to operate it. Thanks in advance.&lt;/FONT&gt;&lt;/P&gt;</description>
      <pubDate>Fri, 05 Feb 2010 01:44:05 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/Help-Using-Labview-to-control-Kikusui-power-supply-with-a/m-p/1066689#M473003</guid>
      <dc:creator>antique</dc:creator>
      <dc:date>2010-02-05T01:44:05Z</dc:date>
    </item>
    <item>
      <title>Re: Help Using Labview to control Kikusui power supply with a PIA4850 controller</title>
      <link>https://ni.lithium.com/t5/LabVIEW/Help-Using-Labview-to-control-Kikusui-power-supply-with-a/m-p/1066698#M473005</link>
      <description>&lt;P&gt;hi antique,&lt;/P&gt;&lt;P&gt;&amp;nbsp; You can download labview drivers for your controller from &lt;/P&gt;&lt;P&gt;&lt;A href="http://" target="_self"&gt;http://www.kikusui.co.jp/en/download/en/archive1.html#PIA4800series&lt;/A&gt;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;&lt;P&gt;Thanks and regards,&lt;/P&gt;&lt;P&gt;srikrishnaNF &lt;/P&gt;&lt;P&gt;&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Fri, 05 Feb 2010 02:30:48 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/Help-Using-Labview-to-control-Kikusui-power-supply-with-a/m-p/1066698#M473005</guid>
      <dc:creator>srikrishnaNF</dc:creator>
      <dc:date>2010-02-05T02:30:48Z</dc:date>
    </item>
    <item>
      <title>Re: Help Using Labview to control Kikusui power supply with a PIA4850 controller</title>
      <link>https://ni.lithium.com/t5/LabVIEW/Help-Using-Labview-to-control-Kikusui-power-supply-with-a/m-p/1067279#M473205</link>
      <description>There are also the &lt;A href="http://sine.ni.com/apps/utf8/niid_web_display.download_page?p_id_guid=E3B19B3E9348659CE034080020E74861" target="_self"&gt;Kikusui ki4800 Power Supply&lt;/A&gt; instrument drivers. This collection of VIs should allow you to control your Power Supply.</description>
      <pubDate>Fri, 05 Feb 2010 19:27:25 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/Help-Using-Labview-to-control-Kikusui-power-supply-with-a/m-p/1067279#M473205</guid>
      <dc:creator>Ben_S</dc:creator>
      <dc:date>2010-02-05T19:27:25Z</dc:date>
    </item>
    <item>
      <title>Re: Help Using Labview to control Kikusui power supply with a PIA4850 controller</title>
      <link>https://ni.lithium.com/t5/LabVIEW/Help-Using-Labview-to-control-Kikusui-power-supply-with-a/m-p/1067587#M473340</link>
      <description>&lt;P style="margin: 0in 0in 0pt" class="MsoNormal"&gt;&lt;FONT face="Times New Roman" size="3" color="#000000"&gt;HI and thanks for the help. I did get one power supply to work but have another problem. I need to control 4 power supplies at the same time and can only operate the one that is addressed N5!C1. If I set the other to N6!C1 and so on I get an error stating &lt;/FONT&gt;&lt;/P&gt;&lt;FONT face="Times New Roman" size="3" color="#000000"&gt;&amp;nbsp;&lt;/FONT&gt;&lt;FONT size="3"&gt;&lt;FONT color="#000000"&gt;&lt;FONT face="Times New Roman"&gt;“Error -1074135008 occurred at ki4800_2 Configure Voltage Level.vi&lt;/FONT&gt;&lt;/FONT&gt;&lt;/FONT&gt;&lt;FONT face="Times New Roman" size="3" color="#000000"&gt;&amp;nbsp;&lt;/FONT&gt;&lt;FONT size="3"&gt;&lt;FONT color="#000000"&gt;&lt;FONT face="Times New Roman"&gt;Possible reason(s):&lt;/FONT&gt;&lt;/FONT&gt;&lt;/FONT&gt;&lt;FONT size="3"&gt;&lt;FONT color="#000000"&gt;&lt;FONT face="Times New Roman"&gt;IVI Error in the method "get_Item" in the component "Kikusui4800".&lt;/FONT&gt;&lt;/FONT&gt;&lt;/FONT&gt; &lt;P style="margin: 0in 0in 0pt" class="MsoNormal"&gt;&lt;FONT face="Times New Roman" size="3" color="#000000"&gt;E_IVI_UNKNOWN_CHANNEL_NAME: Unknown channel name (N6!C1)”&lt;/FONT&gt;&lt;/P&gt;&lt;FONT face="Times New Roman" size="3" color="#000000"&gt;&amp;nbsp;&lt;/FONT&gt; &lt;P style="margin: 0in 0in 0pt" class="MsoNormal"&gt;&lt;FONT face="Times New Roman" size="3" color="#000000"&gt;I am assuming that I should be able to change the node number and that will change the supply that I need to use. Everything works great if I use N5!C1 I can change any of the supplies to address 5 and can control it with no problem. I can even have multiple supplies with the same address N5!C1 (don’t think I should do that) and change them all at once. I need independent control of each supply. &lt;/FONT&gt;&lt;/P&gt;&lt;FONT face="Times New Roman" size="3" color="#000000"&gt;&amp;nbsp;&lt;/FONT&gt; &lt;P style="margin: 0in 0in 0pt" class="MsoNormal"&gt;&lt;FONT face="Times New Roman" size="3" color="#000000"&gt;I am in a pinch here and need to figure it out but could use some help. Any ideas will be greatly appreciated. &lt;/FONT&gt;&lt;/P&gt;&lt;FONT face="Times New Roman" size="3" color="#000000"&gt;&amp;nbsp;&lt;/FONT&gt; &lt;P style="margin: 0in 0in 0pt" class="MsoNormal"&gt;&lt;FONT face="Times New Roman" size="3" color="#000000"&gt;Thanks&lt;/FONT&gt;&lt;/P&gt;&lt;FONT size="3"&gt;&lt;FONT color="#000000"&gt;&lt;FONT face="Times New Roman"&gt;GBlair&lt;EM&gt;&lt;/EM&gt;&lt;/FONT&gt;&lt;/FONT&gt;&lt;/FONT&gt;</description>
      <pubDate>Sun, 07 Feb 2010 18:24:24 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/Help-Using-Labview-to-control-Kikusui-power-supply-with-a/m-p/1067587#M473340</guid>
      <dc:creator>antique</dc:creator>
      <dc:date>2010-02-07T18:24:24Z</dc:date>
    </item>
    <item>
      <title>Re: Help Using Labview to control Kikusui power supply with a PIA4850 controller</title>
      <link>https://ni.lithium.com/t5/LabVIEW/Help-Using-Labview-to-control-Kikusui-power-supply-with-a/m-p/1067631#M473365</link>
      <description>&lt;P style="margin: 0in 0in 0pt" class="MsoNormal"&gt;&lt;FONT face="Times New Roman" size="3" color="#000000"&gt;OK I figured it out. I just overlooked a part in the Kikusui IVI-COM instrument driver programming guide. After installation there is a scan utility that needed to be ran when all of the power supplies are connected? I ran it when I had the first unit connected but had not ran it with all of then connected. Once that was done they were all recognized and worked great. Thanks for the help. &lt;/FONT&gt;&lt;/P&gt;</description>
      <pubDate>Mon, 08 Feb 2010 01:14:00 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/Help-Using-Labview-to-control-Kikusui-power-supply-with-a/m-p/1067631#M473365</guid>
      <dc:creator>antique</dc:creator>
      <dc:date>2010-02-08T01:14:00Z</dc:date>
    </item>