      <title>build using ni 6009</title>
      <link>https://ni.lithium.com/t5/LabVIEW/build-using-ni-6009/m-p/2116356#M687732</link>
      <description>&lt;P&gt;Hi!&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&amp;nbsp; I am trying to build installer&amp;nbsp;for NI USB 6009 to flash LED. To my surprise the application is not flashing LED on target machine. When i test using MAX Test pannel in target machine, it is perfectly ok. The VI&amp;nbsp;without build working fine. I did include LV 2011 spi1 runtime engine&amp;nbsp;and daqmx core runtime. Is it logic?&amp;nbsp;&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Wed, 08 Aug 2012 09:40:39 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/build-using-ni-6009/m-p/2116356#M687732</guid>
      <dc:creator>ssnp</dc:creator>
      <dc:date>2012-08-08T09:40:39Z</dc:date>
    </item>
    <item>
      <title>Re: build using ni 6009</title>
      <link>https://ni.lithium.com/t5/LabVIEW/build-using-ni-6009/m-p/2116396#M687740</link>
      <description>&lt;P&gt;Hi ssnp,&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;I would include the "full" DAQmx installer instead of the DAQmx "core".&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;Then I would encourage you to use "basic" DAQmx functions instead of 4 DAQ assistents. That way you would get error messages quite easily to know what happens (and why)...&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Wed, 08 Aug 2012 10:56:06 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/build-using-ni-6009/m-p/2116396#M687740</guid>
      <dc:creator>GerdW</dc:creator>
      <dc:date>2012-08-08T10:56:06Z</dc:date>
    </item>
    <item>
      <title>Re: build using ni 6009</title>
      <link>https://ni.lithium.com/t5/LabVIEW/build-using-ni-6009/m-p/2116432#M687743</link>
      <description>&lt;P&gt;I have included all daqmx options&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&amp;nbsp; Ni DAQmx applicaiton Development Support&lt;/P&gt;
&lt;P&gt;&amp;nbsp; Ni DAQmx core runtime 9,3.5&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&amp;nbsp; Ni DAqmx MAX configuration support 9.3.5&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;still the same situation.&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Wed, 08 Aug 2012 11:25:21 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/build-using-ni-6009/m-p/2116432#M687743</guid>
      <dc:creator>ssnp</dc:creator>
      <dc:date>2012-08-08T11:25:21Z</dc:date>
    </item>
    <item>
      <title>pulse generator installer</title>
      <link>https://ni.lithium.com/t5/LabVIEW/build-using-ni-6009/m-p/2118154#M688084</link>
      <description>&lt;P&gt;hi!&lt;/P&gt;
&lt;P&gt;&amp;nbsp; My VI is working perfectly fine. When i build it and install it in host machine it is working perfectly fine . But when I install in other machine ( one i tried XP) it is not working. The MAX test panel also communicate with the relay system.&lt;/P&gt;
&lt;P&gt;&amp;nbsp;I am using lv 11 sp 1 in window 7 machine&lt;/P&gt;</description>
      <pubDate>Thu, 09 Aug 2012 15:05:40 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/build-using-ni-6009/m-p/2118154#M688084</guid>
      <dc:creator>ssnp</dc:creator>
      <dc:date>2012-08-09T15:05:40Z</dc:date>
    </item>
    <item>
      <title>Re: pulse generator installer</title>
      <link>https://ni.lithium.com/t5/LabVIEW/build-using-ni-6009/m-p/2118212#M688091</link>
      <description>&lt;P&gt;Did you actually export the hardware configuration from MAX and import it? You don't show that screen and since you are creating a task in MAX, you would obviously need that task on the new pc. The MAX test panel is not relevant in this case.&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;edit - you have no error handling in your VI. Pretty sure if you had done something as basic as this you would have gotten a message indicating what was wrong.&lt;/P&gt;</description>
      <pubDate>Thu, 09 Aug 2012 15:38:22 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/build-using-ni-6009/m-p/2118212#M688091</guid>
      <dc:creator>Dennis_Knutson</dc:creator>
      <dc:date>2012-08-09T15:38:22Z</dc:date>
    </item>
    <item>
      <title>Re: pulse generator installer</title>
      <link>https://ni.lithium.com/t5/LabVIEW/build-using-ni-6009/m-p/2119050#M688258</link>
      <description>&lt;P&gt;I am wondering do I have to export in project explorer or just adding in hardware while building is enough?&lt;/P&gt;</description>
      <pubDate>Fri, 10 Aug 2012 09:08:35 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/build-using-ni-6009/m-p/2119050#M688258</guid>
      <dc:creator>ssnp</dc:creator>
      <dc:date>2012-08-10T09:08:35Z</dc:date>
    </item>
    <item>
      <title>Re: pulse generator installer</title>
      <link>https://ni.lithium.com/t5/LabVIEW/build-using-ni-6009/m-p/2120006#M688425</link>
      <description>&lt;P&gt;The hardware config is part of the installer. There is a category called Hardware Configuration. Check the box there.&lt;/P&gt;</description>
      <pubDate>Fri, 10 Aug 2012 20:53:29 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/build-using-ni-6009/m-p/2120006#M688425</guid>
      <dc:creator>Dennis_Knutson</dc:creator>
      <dc:date>2012-08-10T20:53:29Z</dc:date>
    </item>
    <item>
      <title>Re: pulse generator installer</title>
      <link>https://ni.lithium.com/t5/LabVIEW/build-using-ni-6009/m-p/2120296#M688477</link>
      <description>&lt;P&gt;I tried this . even export the config as ini form host and import in client. still not working&lt;/P&gt;</description>
      <pubDate>Sat, 11 Aug 2012 13:17:49 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/build-using-ni-6009/m-p/2120296#M688477</guid>
      <dc:creator>ssnp</dc:creator>
      <dc:date>2012-08-11T13:17:49Z</dc:date>
    </item>
    <item>
      <title>Re: pulse generator installer</title>
      <link>https://ni.lithium.com/t5/LabVIEW/build-using-ni-6009/m-p/2120420#M688499</link>
      <description>&lt;P&gt;Did you try manually setting up max on the target to verify functionality Vs.. Verifying installer?&lt;/P&gt;</description>
      <pubDate>Sat, 11 Aug 2012 23:41:40 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/build-using-ni-6009/m-p/2120420#M688499</guid>
      <dc:creator>Mark_Ramsdale</dc:creator>
      <dc:date>2012-08-11T23:41:40Z</dc:date>
    </item>
    <item>
      <title>Re: pulse generator installer</title>
      <link>https://ni.lithium.com/t5/LabVIEW/build-using-ni-6009/m-p/2120728#M688582</link>
      <description>&lt;P&gt;if i test using test pannel then it is working fine&lt;/P&gt;</description>
      <pubDate>Mon, 13 Aug 2012 04:01:00 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/build-using-ni-6009/m-p/2120728#M688582</guid>
      <dc:creator>ssnp</dc:creator>
      <dc:date>2012-08-13T04:01:00Z</dc:date>
    </item>
    <item>
      <title>Re: pulse generator installer</title>
      <link>https://ni.lithium.com/t5/LabVIEW/build-using-ni-6009/m-p/2120950#M688629</link>
      <description>&lt;P&gt;I am wondering is there any tool which conform in which stage the NI USB is giving trouble. anytool avilable.&lt;/P&gt;</description>
      <pubDate>Mon, 13 Aug 2012 10:49:12 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/build-using-ni-6009/m-p/2120950#M688629</guid>
      <dc:creator>ssnp</dc:creator>
      <dc:date>2012-08-13T10:49:12Z</dc:date>
    </item>
    <item>
      <title>Re: pulse generator installer</title>
      <link>https://ni.lithium.com/t5/LabVIEW/build-using-ni-6009/m-p/2121186#M688668</link>
      <description>&lt;P&gt;Yes, use proper error handling as I already mentioned. That means adding an error out indicator. That's pretty basic.&lt;/P&gt;</description>
      <pubDate>Mon, 13 Aug 2012 14:26:21 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/build-using-ni-6009/m-p/2121186#M688668</guid>
      <dc:creator>Dennis_Knutson</dc:creator>
      <dc:date>2012-08-13T14:26:21Z</dc:date>
    </item>
    <item>
      <title>Re: pulse generator installer</title>
      <link>https://ni.lithium.com/t5/LabVIEW/build-using-ni-6009/m-p/2121376#M688696</link>
      <description>&lt;P&gt;Hi,&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;I got the impression that you were having difficulty getting the MAX configuration to install on a target machine.&amp;nbsp; So I was suggestion setting up MAX manually on the target to insure your code runs, then focus on why the MAX configuration is not installing.&amp;nbsp;&amp;nbsp; Maybe I got the issue incorrect.&lt;/P&gt;</description>
      <pubDate>Mon, 13 Aug 2012 15:58:40 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/build-using-ni-6009/m-p/2121376#M688696</guid>
      <dc:creator>Mark_Ramsdale</dc:creator>
      <dc:date>2012-08-13T15:58:40Z</dc:date>
    </item>
    <item>
      <title>Re: pulse generator installer</title>
      <link>https://ni.lithium.com/t5/LabVIEW/build-using-ni-6009/m-p/2122826#M688981</link>
      <description>&lt;P&gt;the host machine was window 7 but target machine was window xp( although it was build for it) thats why it was not running. it is fine in window 7. this will solve my problem. thanks you all for your support.&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&amp;nbsp;&amp;nbsp; But another question arrises why it happened.&lt;/P&gt;</description>
      <pubDate>Tue, 14 Aug 2012 15:49:00 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/build-using-ni-6009/m-p/2122826#M688981</guid>
      <dc:creator>ssnp</dc:creator>
      <dc:date>2012-08-14T15:49:00Z</dc:date>
    </item>
    <item>
      <title>Re: pulse generator installer</title>
      <link>https://ni.lithium.com/t5/LabVIEW/build-using-ni-6009/m-p/2122834#M688983</link>
      <description>&lt;P&gt;Thanks!&lt;/P&gt;</description>
      <pubDate>Tue, 14 Aug 2012 15:50:15 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/LabVIEW/build-using-ni-6009/m-p/2122834#M688983</guid>
      <dc:creator>ssnp</dc:creator>
      <dc:date>2012-08-14T15:50:15Z</dc:date>
    </item>
  </channel>
</rss>
