<?xml version="1.0" encoding="UTF-8"?>
<rss xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:taxo="http://purl.org/rss/1.0/modules/taxonomy/" version="2.0">
  <channel>
    <title>topic Re: Channel changing in DASYLab</title>
    <link>https://ni.lithium.com/t5/DASYLab/Channel-changing/m-p/1912011#M2012</link>
    <description>&lt;P&gt;@djmac,&lt;BR /&gt;&lt;BR /&gt;Please update DASYLab 11.0.0 with Service Pack 2.&lt;BR /&gt;Please update NI-DAQmx with 9.5.&lt;BR /&gt;Please check now again the situation.&lt;BR /&gt;&lt;BR /&gt;Best regards,&lt;BR /&gt;MHa&lt;/P&gt;</description>
    <pubDate>Tue, 13 Mar 2012 15:40:22 GMT</pubDate>
    <dc:creator>MHa</dc:creator>
    <dc:date>2012-03-13T15:40:22Z</dc:date>
    <item>
      <title>Channel changing</title>
      <link>https://ni.lithium.com/t5/DASYLab/Channel-changing/m-p/1911657#M2009</link>
      <description>&lt;P&gt;I'm having an issue with Dasylab and NI_MAX. &amp;nbsp;I have two task set-up in MAX. &amp;nbsp;When I use these task in Dasylab it works correctly the first time, but when I run it the second time the channels shift 1 position. &amp;nbsp;(Ex. &amp;nbsp;Output 3 changes to output 2). &amp;nbsp;It stays in the offset configuration. &amp;nbsp;If I then go into MAX the first time I run MAX the channel is shifted 1 location. &amp;nbsp;When I stop and start it it goes back to the correct location. &amp;nbsp;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;I do not not have a problem if I put all the channels in 1 task. &amp;nbsp;Just curious if there is a problem using multiple task in Dasylab.&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;DasyLab 11&lt;/P&gt;
&lt;P&gt;Windows XP sp3&lt;/P&gt;
&lt;P&gt;MAX 5.0&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;Thanks&lt;/P&gt;</description>
      <pubDate>Tue, 13 Mar 2012 12:37:54 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/DASYLab/Channel-changing/m-p/1911657#M2009</guid>
      <dc:creator>djmac</dc:creator>
      <dc:date>2012-03-13T12:37:54Z</dc:date>
    </item>
    <item>
      <title>Re: Channel changing</title>
      <link>https://ni.lithium.com/t5/DASYLab/Channel-changing/m-p/1911749#M2010</link>
      <description>&lt;P&gt;@djmac,&lt;BR /&gt;&lt;BR /&gt;please tell us:&lt;BR /&gt;- the DASYLab version 11.?.?&lt;BR /&gt;- the NI-DAQmx version ?.?.?&lt;BR /&gt;- the used NI-DAQmx device(s) and all details for your created tasks&lt;BR /&gt;&lt;BR /&gt;Is the problem only under DASYLab usage or also under MAX test usage?&lt;BR /&gt;&lt;BR /&gt;Best regards,&lt;BR /&gt;MHa&lt;/P&gt;</description>
      <pubDate>Tue, 13 Mar 2012 13:34:35 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/DASYLab/Channel-changing/m-p/1911749#M2010</guid>
      <dc:creator>MHa</dc:creator>
      <dc:date>2012-03-13T13:34:35Z</dc:date>
    </item>
    <item>
      <title>Re: Channel changing</title>
      <link>https://ni.lithium.com/t5/DASYLab/Channel-changing/m-p/1911917#M2011</link>
      <description>&lt;P&gt;Dasylab 11.0.0&lt;/P&gt;
&lt;P&gt;NI DAQ MX = 5.0.0f1&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;DAQmx Devices&lt;/P&gt;
&lt;P&gt;-9174&lt;/P&gt;
&lt;P&gt;- 9219 (2)&lt;/P&gt;
&lt;P&gt;- 9213&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;I have&amp;nbsp;temp task whick has 9 channels (0-9) on the 9213. I also have a voltage task that use 4 channels on the first 9219 and 2 channels on the second 9213 (ch 0 and Ch 2).&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;If i just run MAX it is not a problem.&amp;nbsp; The proplem occurs after running dasylab.&amp;nbsp; Below is the sequence that causes problems&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;1.&amp;nbsp; Run task in MAX (Good)&lt;/P&gt;
&lt;P&gt;2. Run in Dasylab (Good)&lt;/P&gt;
&lt;P&gt;3. Stop and restart dasylab (Values shift)&lt;/P&gt;
&lt;P&gt;4. Run task in MAX (Values are still shifted)&lt;/P&gt;
&lt;P&gt;5. Stop and restart MAX (Good)&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;When exiting out of both DasyLab and MAX they both ask if I want to save changes, even though I have not changed any settings.&amp;nbsp; I have had this problem on another setup as well.&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;Thanks for the help&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Tue, 13 Mar 2012 14:57:32 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/DASYLab/Channel-changing/m-p/1911917#M2011</guid>
      <dc:creator>djmac</dc:creator>
      <dc:date>2012-03-13T14:57:32Z</dc:date>
    </item>
    <item>
      <title>Re: Channel changing</title>
      <link>https://ni.lithium.com/t5/DASYLab/Channel-changing/m-p/1912011#M2012</link>
      <description>&lt;P&gt;@djmac,&lt;BR /&gt;&lt;BR /&gt;Please update DASYLab 11.0.0 with Service Pack 2.&lt;BR /&gt;Please update NI-DAQmx with 9.5.&lt;BR /&gt;Please check now again the situation.&lt;BR /&gt;&lt;BR /&gt;Best regards,&lt;BR /&gt;MHa&lt;/P&gt;</description>
      <pubDate>Tue, 13 Mar 2012 15:40:22 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/DASYLab/Channel-changing/m-p/1912011#M2012</guid>
      <dc:creator>MHa</dc:creator>
      <dc:date>2012-03-13T15:40:22Z</dc:date>
    </item>
    <item>
      <title>Re: Channel changing</title>
      <link>https://ni.lithium.com/t5/DASYLab/Channel-changing/m-p/1913315#M2013</link>
      <description>&lt;P&gt;Installed all updates and still have the same issue. &amp;nbsp;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;Thanks&lt;/P&gt;</description>
      <pubDate>Wed, 14 Mar 2012 13:16:25 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/DASYLab/Channel-changing/m-p/1913315#M2013</guid>
      <dc:creator>djmac</dc:creator>
      <dc:date>2012-03-14T13:16:25Z</dc:date>
    </item>
    <item>
      <title>Re: Channel changing</title>
      <link>https://ni.lithium.com/t5/DASYLab/Channel-changing/m-p/1913587#M2014</link>
      <description>&lt;P&gt;@djmac,&lt;BR /&gt;&lt;BR /&gt;&lt;/P&gt;
&lt;P&gt;1. Run task in MAX (Good)&lt;/P&gt;
&lt;P&gt;2. Run in Dasylab (Good)&lt;/P&gt;
&lt;P&gt;&lt;STRONG&gt;3. Stop and restart dasylab (Values shift) -&amp;gt; sounds that any API command from DASYLab for NI-DAQmx generate a reinit problem.&lt;/STRONG&gt;&lt;BR /&gt;4. Run task in MAX (Values are still shifted)&lt;/P&gt;
&lt;P&gt;5. Stop and restart MAX (Good)&lt;BR /&gt;&lt;BR /&gt;Please attach&lt;BR /&gt;- your DASYLab worksheet&lt;BR /&gt;- your MAX task configuration&lt;BR /&gt;- a NISpy Log from DASYLab NI-DAQmx calls&lt;BR /&gt;to this thread. I would like think about the problem. Thanks.&lt;BR /&gt;&lt;BR /&gt;Best regards,&lt;/P&gt;
&lt;P&gt;MHa&lt;/P&gt;</description>
      <pubDate>Wed, 14 Mar 2012 15:59:10 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/DASYLab/Channel-changing/m-p/1913587#M2014</guid>
      <dc:creator>MHa</dc:creator>
      <dc:date>2012-03-14T15:59:10Z</dc:date>
    </item>
    <item>
      <title>Re: Channel changing</title>
      <link>https://ni.lithium.com/t5/DASYLab/Channel-changing/m-p/1926091#M2018</link>
      <description>&lt;P&gt;@djmac,&lt;BR /&gt;&lt;BR /&gt;please send me the infos. Otherwise I can't help.&lt;BR /&gt;&lt;BR /&gt;Best regards,&lt;/P&gt;
&lt;P&gt;MHa&lt;BR /&gt;&lt;BR /&gt;&lt;/P&gt;</description>
      <pubDate>Fri, 23 Mar 2012 19:02:39 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/DASYLab/Channel-changing/m-p/1926091#M2018</guid>
      <dc:creator>MHa</dc:creator>
      <dc:date>2012-03-23T19:02:39Z</dc:date>
    </item>
    <item>
      <title>Re: Channel changing</title>
      <link>https://ni.lithium.com/t5/DASYLab/Channel-changing/m-p/1940247#M2034</link>
      <description>&lt;P&gt;Sorry for the delay.&amp;nbsp; Here is the info.&amp;nbsp; Let me know if you need any thing else&lt;/P&gt;</description>
      <pubDate>Wed, 04 Apr 2012 19:03:10 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/DASYLab/Channel-changing/m-p/1940247#M2034</guid>
      <dc:creator>djmac</dc:creator>
      <dc:date>2012-04-04T19:03:10Z</dc:date>
    </item>
    <item>
      <title>Re: Channel changing</title>
      <link>https://ni.lithium.com/t5/DASYLab/Channel-changing/m-p/1945267#M2054</link>
      <description>&lt;P&gt;@djmac,&lt;BR /&gt;&lt;BR /&gt;please send me also your MAX device / task configuration. I don't have the info which device(s) you use and which type of task. Thanks.&lt;BR /&gt;&lt;BR /&gt;Best regards,&lt;BR /&gt;MHa&lt;/P&gt;</description>
      <pubDate>Tue, 10 Apr 2012 06:50:39 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/DASYLab/Channel-changing/m-p/1945267#M2054</guid>
      <dc:creator>MHa</dc:creator>
      <dc:date>2012-04-10T06:50:39Z</dc:date>
    </item>
    <item>
      <title>Re: Channel changing</title>
      <link>https://ni.lithium.com/t5/DASYLab/Channel-changing/m-p/1945629#M2056</link>
      <description>&lt;P&gt;Do you need more info than what is provided in the "max report" html file?&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Tue, 10 Apr 2012 12:00:38 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/DASYLab/Channel-changing/m-p/1945629#M2056</guid>
      <dc:creator>djmac</dc:creator>
      <dc:date>2012-04-10T12:00:38Z</dc:date>
    </item>
    <item>
      <title>Re: Channel changing</title>
      <link>https://ni.lithium.com/t5/DASYLab/Channel-changing/m-p/1945633#M2057</link>
      <description>&lt;P&gt;Yes, the MAX export file *.nce with included tasks and device would be more helpful.&lt;/P&gt;</description>
      <pubDate>Tue, 10 Apr 2012 12:04:29 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/DASYLab/Channel-changing/m-p/1945633#M2057</guid>
      <dc:creator>MHa</dc:creator>
      <dc:date>2012-04-10T12:04:29Z</dc:date>
    </item>
    <item>
      <title>Re: Channel changing</title>
      <link>https://ni.lithium.com/t5/DASYLab/Channel-changing/m-p/1951503#M2068</link>
      <description>&lt;P&gt;I tried to attach the .nce file and it gives me an error saying that its not an acceptable extension for an attachment.&amp;nbsp; What would you like me to do&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;Thanks&lt;/P&gt;</description>
      <pubDate>Fri, 13 Apr 2012 18:14:58 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/DASYLab/Channel-changing/m-p/1951503#M2068</guid>
      <dc:creator>djmac</dc:creator>
      <dc:date>2012-04-13T18:14:58Z</dc:date>
    </item>
    <item>
      <title>Re: Channel changing</title>
      <link>https://ni.lithium.com/t5/DASYLab/Channel-changing/m-p/1952769#M2070</link>
      <description>&lt;P&gt;Please 'hide' the NCE-file in a ZIP-archive.&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;BTW:&lt;/P&gt;
&lt;P&gt;May be a nice augmentation to this NI-forum, if it's possible to attach files-formats used in NI-software... &lt;span class="lia-unicode-emoji" title=":winking_face:"&gt;😉&lt;/span&gt;&lt;/P&gt;</description>
      <pubDate>Mon, 16 Apr 2012 09:25:47 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/DASYLab/Channel-changing/m-p/1952769#M2070</guid>
      <dc:creator>hw70</dc:creator>
      <dc:date>2012-04-16T09:25:47Z</dc:date>
    </item>
    <item>
      <title>Re: Channel changing</title>
      <link>https://ni.lithium.com/t5/DASYLab/Channel-changing/m-p/1964353#M2106</link>
      <description>&lt;P&gt;Attached is the NCE file.&amp;nbsp; Sorry for the delay, I've been on vacation&lt;/P&gt;</description>
      <pubDate>Tue, 24 Apr 2012 17:59:52 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/DASYLab/Channel-changing/m-p/1964353#M2106</guid>
      <dc:creator>djmac</dc:creator>
      <dc:date>2012-04-24T17:59:52Z</dc:date>
    </item>
    <item>
      <title>Re: Channel changing</title>
      <link>https://ni.lithium.com/t5/DASYLab/Channel-changing/m-p/1971057#M2110</link>
      <description>&lt;P&gt;@djmac,&lt;BR /&gt;&lt;BR /&gt;I have used your configData1.zip MAX settings and your last DASYLab worksheet. I'm use DASYLab 12.0.x and get from DASYLab NI-DAQmx driver an error message if I load the DSB:&lt;BR /&gt;&lt;BR /&gt;- task MyVoltageTask -&amp;gt; The synchronization load from MAX into DASYLab say me that the task have an internal sampling rate = 0.0. This based on an error from NI-DAQmx API outside from DASYLab. A workarround is only if you change the MAX task mode "continuous" into 1 value spoftware polled. Is this possible for you? Please check now the swapping situation for your application.&lt;BR /&gt;&lt;BR /&gt;Best regards,&lt;/P&gt;
&lt;P&gt;MHa&lt;/P&gt;</description>
      <pubDate>Mon, 30 Apr 2012 08:30:59 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/DASYLab/Channel-changing/m-p/1971057#M2110</guid>
      <dc:creator>MHa</dc:creator>
      <dc:date>2012-04-30T08:30:59Z</dc:date>
    </item>
  </channel>
</rss>
