<?xml version="1.0" encoding="UTF-8"?>
<rss xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:taxo="http://purl.org/rss/1.0/modules/taxonomy/" version="2.0">
  <channel>
    <title>topic Re: data trigger to solid state relay in DASYLab</title>
    <link>https://ni.lithium.com/t5/DASYLab/data-trigger-to-solid-state-relay/m-p/2425762#M2575</link>
    <description>&lt;P&gt;Thank you to&amp;nbsp;CJ ,Jeff ,Tom&amp;nbsp;and any others I forgot ,for all&amp;nbsp;for your patience and knowledge.&lt;/P&gt;
&lt;P&gt;Program is running great. &lt;img id="smileylol" class="emoticon emoticon-smileylol" src="https://ni.lithium.com/i/smilies/16x16_smiley-lol.gif" alt="Smiley LOL" title="Smiley LOL" /&gt; Kent.&lt;/P&gt;</description>
    <pubDate>Wed, 15 May 2013 12:38:35 GMT</pubDate>
    <dc:creator>KCL64</dc:creator>
    <dc:date>2013-05-15T12:38:35Z</dc:date>
    <item>
      <title>data trigger to solid state relay</title>
      <link>https://ni.lithium.com/t5/DASYLab/data-trigger-to-solid-state-relay/m-p/2424412#M2557</link>
      <description>&lt;P&gt;I would like to take 2 channels from a data trigger and have them hold a&amp;nbsp;solidstate relay closed until the trigger event.&lt;/P&gt;
&lt;P&gt;Any idea's what module could I use to perform this task.?&amp;nbsp; Thanks. Kent&lt;/P&gt;</description>
      <pubDate>Tue, 14 May 2013 15:20:42 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/DASYLab/data-trigger-to-solid-state-relay/m-p/2424412#M2557</guid>
      <dc:creator>KCL64</dc:creator>
      <dc:date>2013-05-14T15:20:42Z</dc:date>
    </item>
    <item>
      <title>Re: data trigger to solid state relay</title>
      <link>https://ni.lithium.com/t5/DASYLab/data-trigger-to-solid-state-relay/m-p/2424652#M2562</link>
      <description>&lt;P&gt;Kent,&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;I need a bit more explanation. Is the data trigger the DASYLab Data Trigger module or is it a Digital Input?&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;...until the trigger event.... what trigger event?&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;I would look at the Latch module or the FlipFlop module.&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Tue, 14 May 2013 17:24:00 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/DASYLab/data-trigger-to-solid-state-relay/m-p/2424652#M2562</guid>
      <dc:creator>CJ_Butler__DASYLab_Pro</dc:creator>
      <dc:date>2013-05-14T17:24:00Z</dc:date>
    </item>
    <item>
      <title>Re: data trigger to solid state relay</title>
      <link>https://ni.lithium.com/t5/DASYLab/data-trigger-to-solid-state-relay/m-p/2424664#M2564</link>
      <description>&lt;P&gt;Sorry ,It's a dasylab data trigger module setup to trigger within the limits I have set.&lt;/P&gt;
&lt;P&gt;The data&amp;nbsp;trigger works on my status indicators, green for good, red for bad . When the staus is&lt;/P&gt;
&lt;P&gt;green I require a NC solidstate control&amp;nbsp;relay and when it goes red I require&amp;nbsp;that relay to open.&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Tue, 14 May 2013 17:33:18 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/DASYLab/data-trigger-to-solid-state-relay/m-p/2424664#M2564</guid>
      <dc:creator>KCL64</dc:creator>
      <dc:date>2013-05-14T17:33:18Z</dc:date>
    </item>
    <item>
      <title>Re: data trigger to solid state relay</title>
      <link>https://ni.lithium.com/t5/DASYLab/data-trigger-to-solid-state-relay/m-p/2424676#M2565</link>
      <description>&lt;P&gt;I tried using a digital output but I believe because I'm using the analog input to get my required speed this is not possible. Is there a way of programming and&lt;/P&gt;
&lt;P&gt;wiring an analog output to control this solidstate relay.&lt;/P&gt;</description>
      <pubDate>Tue, 14 May 2013 17:44:07 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/DASYLab/data-trigger-to-solid-state-relay/m-p/2424676#M2565</guid>
      <dc:creator>KCL64</dc:creator>
      <dc:date>2013-05-14T17:44:07Z</dc:date>
    </item>
    <item>
      <title>Re: data trigger to solid state relay</title>
      <link>https://ni.lithium.com/t5/DASYLab/data-trigger-to-solid-state-relay/m-p/2424714#M2566</link>
      <description>&lt;P&gt;Which hardware are you using?&lt;/P&gt;</description>
      <pubDate>Tue, 14 May 2013 17:59:17 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/DASYLab/data-trigger-to-solid-state-relay/m-p/2424714#M2566</guid>
      <dc:creator>TomRizzo</dc:creator>
      <dc:date>2013-05-14T17:59:17Z</dc:date>
    </item>
    <item>
      <title>Re: data trigger to solid state relay</title>
      <link>https://ni.lithium.com/t5/DASYLab/data-trigger-to-solid-state-relay/m-p/2424726#M2567</link>
      <description>&lt;P&gt;Hi Tom&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;USB-1208FS&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&amp;nbsp; Analog subsystem&lt;/P&gt;
&lt;P&gt;5000Hz / 100 samples/block&lt;/P&gt;
&lt;P&gt;Works great at my speed requirement. CJ and Jeff helped me out of a bind when they suggested going to&amp;nbsp;analog instead of the slower digital sub system.&lt;/P&gt;
&lt;P&gt;But I still require a way to get a signal out to my machines solid state relay for a stop command when the data goes out of range and&amp;nbsp;status goes red.&lt;/P&gt;</description>
      <pubDate>Tue, 14 May 2013 18:06:30 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/DASYLab/data-trigger-to-solid-state-relay/m-p/2424726#M2567</guid>
      <dc:creator>KCL64</dc:creator>
      <dc:date>2013-05-14T18:06:30Z</dc:date>
    </item>
    <item>
      <title>Re: data trigger to solid state relay</title>
      <link>https://ni.lithium.com/t5/DASYLab/data-trigger-to-solid-state-relay/m-p/2424784#M2568</link>
      <description>&lt;P&gt;To my understanding, I also have a 1208FS in my stock, you should be able to connect it with a digital output very easyly.&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;The manual would explain it how to do it wire it.&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;Obviusly, do not expect a super fast reaction but it should be good enough.&lt;/P&gt;</description>
      <pubDate>Tue, 14 May 2013 18:45:41 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/DASYLab/data-trigger-to-solid-state-relay/m-p/2424784#M2568</guid>
      <dc:creator>TomRizzo</dc:creator>
      <dc:date>2013-05-14T18:45:41Z</dc:date>
    </item>
    <item>
      <title>Re: data trigger to solid state relay</title>
      <link>https://ni.lithium.com/t5/DASYLab/data-trigger-to-solid-state-relay/m-p/2424810#M2569</link>
      <description>&lt;P&gt;I have tried to add a digital output but it seems to slow down the analog input also.&lt;/P&gt;
&lt;P&gt;I will test further this way to see what's really going on. The digital output speed is&lt;/P&gt;
&lt;P&gt;not as big a factor in this experiment.&amp;nbsp; Thanks Kent.&lt;/P&gt;</description>
      <pubDate>Tue, 14 May 2013 18:55:41 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/DASYLab/data-trigger-to-solid-state-relay/m-p/2424810#M2569</guid>
      <dc:creator>KCL64</dc:creator>
      <dc:date>2013-05-14T18:55:41Z</dc:date>
    </item>
    <item>
      <title>Re: data trigger to solid state relay</title>
      <link>https://ni.lithium.com/t5/DASYLab/data-trigger-to-solid-state-relay/m-p/2424828#M2570</link>
      <description>&lt;P&gt;That is strange, when you're done with the design, post it and maybe we can quickly test it&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Tue, 14 May 2013 19:01:15 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/DASYLab/data-trigger-to-solid-state-relay/m-p/2424828#M2570</guid>
      <dc:creator>TomRizzo</dc:creator>
      <dc:date>2013-05-14T19:01:15Z</dc:date>
    </item>
    <item>
      <title>Re: data trigger to solid state relay</title>
      <link>https://ni.lithium.com/t5/DASYLab/data-trigger-to-solid-state-relay/m-p/2424852#M2571</link>
      <description>&lt;P&gt;It doesn't appear that It will let me use&amp;nbsp;a digital output with out changing my scan rate.&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Tue, 14 May 2013 19:15:53 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/DASYLab/data-trigger-to-solid-state-relay/m-p/2424852#M2571</guid>
      <dc:creator>KCL64</dc:creator>
      <dc:date>2013-05-14T19:15:53Z</dc:date>
    </item>
    <item>
      <title>Re: data trigger to solid state relay</title>
      <link>https://ni.lithium.com/t5/DASYLab/data-trigger-to-solid-state-relay/m-p/2424900#M2572</link>
      <description>&lt;P&gt;What you need to do is separate the input process with the output.&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;To do that you can use variables and sync them with the respective sample rate.&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;The only issue you will have is that there will be a block delay from the trigger moment to the reaction.&amp;nbsp; In your case 100 samples or 20 ms or the sample rate your are going to use for the output.&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;Use the Driver time base to define the digital output rate.&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;</description>
      <pubDate>Tue, 14 May 2013 19:48:21 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/DASYLab/data-trigger-to-solid-state-relay/m-p/2424900#M2572</guid>
      <dc:creator>TomRizzo</dc:creator>
      <dc:date>2013-05-14T19:48:21Z</dc:date>
    </item>
    <item>
      <title>Re: data trigger to solid state relay</title>
      <link>https://ni.lithium.com/t5/DASYLab/data-trigger-to-solid-state-relay/m-p/2424910#M2573</link>
      <description>&lt;P&gt;Now is the time to disconnect the inputs from the output.&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;What you are going to want to do is to delete the wires to the Digital Output.&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;Now create a Control-Write Variable module with two channels -- it defaults to variable 1 and 2 - if you aren't using variables, leave it that way.&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;Connect the wires that used to go to the Digital Output to the Write Variable module.&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;Create a Read Variable module. Configure it with two channels, and change the time base to DASYLab. That should be 10s/sec, block size 1.&lt;/P&gt;
&lt;P&gt;Connect the Read variable module to the Digital output. It's now going to work with a 100 ms update rate.&lt;/P&gt;
&lt;P&gt;&amp;nbsp;&lt;/P&gt;
&lt;P&gt;Note - if you didn't use variables 1 and 2, ensure that both the read and write variable modules match.&lt;/P&gt;</description>
      <pubDate>Tue, 14 May 2013 20:02:27 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/DASYLab/data-trigger-to-solid-state-relay/m-p/2424910#M2573</guid>
      <dc:creator>CJ_Butler__DASYLab_Pro</dc:creator>
      <dc:date>2013-05-14T20:02:27Z</dc:date>
    </item>
    <item>
      <title>Re: data trigger to solid state relay</title>
      <link>https://ni.lithium.com/t5/DASYLab/data-trigger-to-solid-state-relay/m-p/2425762#M2575</link>
      <description>&lt;P&gt;Thank you to&amp;nbsp;CJ ,Jeff ,Tom&amp;nbsp;and any others I forgot ,for all&amp;nbsp;for your patience and knowledge.&lt;/P&gt;
&lt;P&gt;Program is running great. &lt;img id="smileylol" class="emoticon emoticon-smileylol" src="https://ni.lithium.com/i/smilies/16x16_smiley-lol.gif" alt="Smiley LOL" title="Smiley LOL" /&gt; Kent.&lt;/P&gt;</description>
      <pubDate>Wed, 15 May 2013 12:38:35 GMT</pubDate>
      <guid>https://ni.lithium.com/t5/DASYLab/data-trigger-to-solid-state-relay/m-p/2425762#M2575</guid>
      <dc:creator>KCL64</dc:creator>
      <dc:date>2013-05-15T12:38:35Z</dc:date>
    </item>
  </channel>
</rss>
