Clearing DAQmx AO task takes long time

Thanks for the answer.

Just to be clear, in your case you changed the data aquisition card and stayed with the new 64bit controller, and everything worked again?

0 Kudos
Message 11 of 13
(828 Views)

I am sorry, I was wrong about fixing the I/O card. The issue was in the NI PXie-1071 chassis. I didn't buy anything new; NI repaired the chassis and sent me a loaner while they were debugging/fixing mine.

Message 12 of 13
(826 Views)

Ok. This is also what we suspect at the moment. The issue is probably somewhere on the backplane of the chassis since we run all the proposed tests (switching cards, switching slots, switching controllers) and it did not resolve the problem.

 

Thanks for your big help anyway!

0 Kudos
Message 13 of 13
(817 Views)