05-21-2002 03:16 PM
05-22-2002
09:06 AM
- last edited on
05-29-2025
03:34 PM
by
Content Cleaner
If you're using the version of VISA that shipped with LabVIEW 6, then you'll have to download something more recent. You can get it here
05-22-2002
02:03 PM
- last edited on
05-29-2025
03:35 PM
by
Content Cleaner
LabVIEW 6.0 (ships w/ VISA 2.5) and VISA 2.5.2 were released prior to the release of Windows XP, so it does not officially support Windows XP. However, we have been able to test it with this operating system, NI-VISA 2.5.2 and LabVIEW 6.0 install and load properly on Windows XP.
Serial and ethernet hardware should work fine, except for known issues that would be seen on any Win32 operating system
NI-VISA 2.6 and LabVIEW 6.1 (ships with NI-VISA 2.6) are the first versions that officially support Windows XP.
Ray K
Applications Engineer
National Instruments