Hi,

 

I'm completely new to Labview and I'm working on a project that includes controlling CANalyzer from LabView by an ActiveX control.

 

In CANalyzer I have a CAPL function that I need to call from LV. The problem is that the function must be created in the onInit event when starting a canalyzer measurement. The only way I have found to create the function is to use a "reg event call back" and create the function in a "static vi reference". This works and I can call the funtion from that vi, but I'm not able to call the function from anywhere else but from the "static vi reference" and since it must be strictly typed I can not add any output connector where I can add a reference.

I've been trying to solve this for thee days now and it's starting to feel hope less.

 

In VB the complete code would look something like:

    Dim WithEvents gCANApp As CANalyzer.Application
    Dim WithEvents gMeasurement As CANalyzer.Measurement
    Dim gSendFunction As CANalyzer.CAPLFunction
    Dim Y

    Set gCANApp = New CANalyzer.Application
    gCANApp.Open ("C:\...xxxx.cfg")
    Set gMeasurement = gCANApp.Measurement
    gMeasurement.Start
    gSendFunction.Call

 

   'Measurement OnInit event handler

   Private Sub gMeasurement_OnInit()
       Set gSendFunction = gCANApp.CAPL.GetFunction("MyFunction")

   End Sub

 

This would work fine since I have a reference to gSendFunction in my main code.

 

My LV code looks like this:

main.PNG

and my static vi ref looks like this:

vi ref.PNG

What I think I need is a reference to the data thread coming from "GetFunction"

 

If any one can help me solve this I would be very happy!

 

 

Best Regards

Henrik

0 Kudos
Message 1 of 3
(3,076 Views)

Hi,

 

you could add another input to your static vi ref where you input the reference to a reference display element which sits in your other vi (upper image).

Then you could make a signaling value change to the reference display element from within your static vi ref.

In your other vi set up an event structure to detect the value change. In that event close the vi - this will let you have the desired reference as output of that vi.

 

Regards Florian

0 Kudos
Message 2 of 3
(2,950 Views)

Hi Henrik,

 

Im also trying to access the CANoe CAPL function from the Labview but i struggling to do that. I done for remaining Signal read, EV read/write and all now i am struggling to access the CAPL. if you found any approach please share.

 

 

Thanks in Advance,

Kalanga

0 Kudos