Hi Andy,
I've upgraded DAQmx to 8.0.1 and the installer build now works....sometimes.
And sometimes it gives me a different error:
CDK_Build_Invoke.vi.ProxyCaller >> CDK_Build_Invoke.vi >> CDK_Engine_Main.vi >> CDK_Engine_Build.vi >> NI_MDF.lvlib:MDFBuildDist_Build.vi
Loading product deployment information
Loading product deployment information
Loading product deployment information
Loading product deployment information
Loading product deployment information
Adding files to installer
Done adding files
Preparing to build deployment
Copying products from distributions
Copying distribution 'NI-DAQ 8.0.1' from: C:\Documents and Settings\brettper\Desktop\NIDAQ801\8.0.1\ to: C:\Documents and Settings\brettper\My Documents\Work\Deakin University\433 VuPlate Software Upgrade\builds\VUPlate\VuPlate Installer\
Copying distribution 'Setup' from: C:\Documents and Settings\brettper\My Documents\Work\Deakin University\433 VuPlate Software Upgrade\builds\VUPlate\VuPlate Installer\Volume\ to: C:\Documents and Settings\brettper\My Documents\Work\Deakin University\433 VuPlate Software Upgrade\builds\VUPlate\VuPlate Installer\
Building deployment
Copying setup files
Setting merged database information
Setting product information
Setting developer part information
Starting final build
Validating...
**************
*** Error: An internal tool or library returned an error. (Error code -21)
Error Messages
Input directory 'C:\Documents and Settings\brettper\My Documents\Work\Deakin University\433 VuPlate Software Upgrade\builds\VUPlate\VuPlate Installer\Volume\bin\p2' not found for part 'palSetupLVRT.msi' in product 'C:\Program Files\National Instruments\Shared\MDF\Manifests\NI-PAL for Phar Lap ETS {3263845B-95F2-43C0-817E-B7BF25BCB742}.xml'.
Input directory 'C:\Documents and Settings\brettper\My Documents\Work\Deakin University\433 VuPlate Software Upgrade\builds\VUPlate\VuPlate Installer\Volume\bin\p3' not found for part 'infInstaller.msi' in product 'C:\Program Files\National Instruments\Shared\MDF\Manifests\NI-DAQ INF Files {2146CF1A-5ACD-4A50-8B36-6A7DD095B08C}.xml'.
-- SNIP --
Input directory 'C:\Documents and Settings\brettper\My Documents\Work\Deakin University\433 VuPlate Software Upgrade\builds\VUPlate\VuPlate Installer\Volume\bin\p43\nilm' not found for part 'nilm.msi' in product 'C:\Program Files\National Instruments\Shared\MDF\Manifests\NI License Manager {FB6DF036-C3A7-4A89-92DA-B4364A8E9373}.xml'.
Input directory 'C:\Documents and Settings\brettper\My Documents\Work\Deakin University\433 VuPlate Software Upgrade\builds\VUPlate\VuPlate Installer\Volume\bin\p44\LVRealTimeErrorDialog' not found for part 'LVRealTimeErrorDialog.msi' in product 'C:\Program Files\National Instruments\Shared\MDF\Manifests\NI LabVIEW RT Error Dialog {3DFF45F7-C12C-4A3A-BA9E-1946A4E92424}.xml'.
Input directory 'C:\Documents and Settings\brettper\My Documents\Work\Deakin University\433 VuPlate Software Upgrade\builds\VUPlate\VuPlate Installer\Volume\bin\p45\LVBrokerAux800' not found for part 'LVBrokerAux80.msi' in product 'C:\Program Files\National Instruments\Shared\MDF\Manifests\Broker Aux 8.0 {88BBB9A9-C034-466E-BB83-8197AFD1669C}.xml'.
*** End Error Report
**************
Done building deployment
---
And underneath all this (in the Details of the Build Errors dialog) I get
"Visit the Request Support page at ni.com/ask to learn more about resolving this problem. Use the following information as a reference:"
followed by nothing...
So it's sort of working but not entirely reliable. I think I've seen the path to the DAQmx installer in the Additional Installers tab replaced with the path into the installer build directory I was being prompted with earlier but I haven't been able to replicate this.