Hello!
In my main vi I have a cluster of 6 waveform graphs. I will update these graphs from a sub vi and sends therefore the cluster property "controls" to my sub vi. In the sub vi I use the array index to get the right control property and writes the array that I want to show up in the graph. This work fine as long as I only writes a 1-dimensional array to the property. But I want to have 2 waves in my graph and therefore writes a 2-dimensional array to the property. This does not work by some reason. If I write the 2-dimensional array directly to a graph that is not inside a cluster there is no problem.
Please help me!
tj
0 Kudos
Message 1 of 2
(2,438 Views)
Hello
Basically, you can wire to a value property node the same type of data you wired originally to the terminal.

By default, a graph array is a 1D array of data. Should you want to wire a 2D array, init the graph for 2D. See attached doc. Obviously, if graph is for 2d, you can not wire 1D, but you can create a 2D from 1D and use it.


Hope it helps

Alipio
---------------------------------------------------------
"Qod natura non dat, Salmantica non praestat"
---------------------------------------------------------
0 Kudos