LabVIEW

cancel
Showing results for 
Search instead for 
Did you mean: 

VISA property not present in LabVIEW 6.0.2.

VISA property "Serial Settings>Break Length" not available.
I created a VISA Property node then attempted to select the property from the popup list.

Thanks for any reply. :}
0 Kudos
Message 1 of 5
(3,033 Views)
Which version of VISA is installed? I think this property wasn't available until VISA 2.6. LabVIEW 6.0.2 is shipped with an earlier version. Upgrade VISA and you'll be able to use the property.


LabVIEW, C'est LabVIEW

0 Kudos
Message 2 of 5
(3,033 Views)
I had installed VISA 2.6 and looked for the property in both LabVIEW and VISA Interactive Control with no luck.
I did find the property in a header file. "C:\VXIpnp\WinNT\include\visa.h". Have no idea what it's there for other than maybe a macro for use with C progromming or CVI.
I will try uninstalling VISA and give it another try. Thanks for the response.
0 Kudos
Message 3 of 5
(3,033 Views)
I had the same problem about 1 year ago. This was the answer from NI :

It turns out that when you update to NI-VISA 2.6.0, we do not actually update the visarc file in the LabVIEW 6.0x directory. We will try to fix that in a future version of our installer. For now, just copy the attached file into your LabVIEW\resource directory.
Message 4 of 5
(3,033 Views)
Thank you JB! That fixes it. :}}
Thanks to others who replied also.
0 Kudos
Message 5 of 5
(3,033 Views)