LabVIEW

cancel
Showing results for 
Search instead for 
Did you mean: 

error -1950679035 latches,restart the SVE service only possible?

Hello,
 
I am developing and testing my application on my windows 2000pro PC. with Labview 8.21.
On local host I am testing a simulated target, a host program and a client program (much like NI example).
When I start target or client program before the host program, error -1950679035 appears, which I can understand, but restarting in the right order does not clear this error.
The only way it is cleared is when I restart the SVE in windows services.
After that, starting in the wrong order again ,which generates the error again, this error does NOT latch. (is cleared after restarting in the right order.)
 
This "error-latch"appeares every day I start my computer so I think it has something to do about power-up dependancy of the SVE..??
 
Is this a known "bug"?
Is manualy restarting the service the only option?
 
I tried to build a Labview exe which runs a windows SDK program called "sc.exe" ,sequence:  sc stop NITaggerService -delay-start NITaggerService-delay which
runs ok in edit mode but after build to exe and run it, windows comes with "this application is not responding, exit".
(I wanted to put this exe in my PC startup)
 
Kind regards,
 
Frank
 
0 Kudos
Message 1 of 2
(2,947 Views)

Installed Labview 8.50.

Problem disappeared.

Frank

 

0 Kudos
Message 2 of 2
(2,901 Views)