Counter/Timer

cancel
Showing results for 
Search instead for 
Did you mean: 

M-Series PFI lines allotment

Is it possible to allocate a digital signal to each PFI line individually for counter 0/1?
I mean, e.g., default counter/timer pinout for CTR 0 GATE is PFI 9.
Now, I would like to configurate this terminal to an other PFI line (e.g. PFI 5).
Can I do this with LabVIEW?
 
I use NI PCI-6229 with LabVIEW 8.0
 
thanks for answers
0 Kudos
Message 1 of 3
(3,609 Views)
In the following a screenshot, how I tried to solve my problem:
 
 
but without success...(it doesn't work)
0 Kudos
Message 2 of 3
(3,604 Views)
Since this is a frequency measurement task, you'll want to change the frequency input terminal using the channel property node as shown in the attachment.
 
Channel Property Node >> Counter Input >> Frequency >> Input Terminal
 
gus....
 
 
0 Kudos
Message 3 of 3
(3,587 Views)