:-( NEED HELP: digital counter

Greetings friends, first of all ... Thanks for your time and read this post.
 
 
I was looking at other publications on this topic and somehow solved already, however, when I download the examples can not get to them because the programming is in LABVIEW 2011 or 2012 .... : smileysad: and I have is labview 2010.
 
good .... They know I'm connecting a 6009 ENCODER my DAQ, the encoder sends a pulse to the DAQ and I want to count how many pulses sent ....
I know you can use in the PFI O, but in my case I do not use are demanding that port, but that makes a digital counter .... Here I leave a picture of what I programmed.
 


Dibujo.JPG
 
What I can not do is that every time you send a pulse DAQ, the program agrege ONLY numbers and NO more to counter the massive amount of numbers you added when "just" the DAQ sends a single pulse.
 
finally ... Acurio I also put a "TIMING" retarded, but I like the idea of condemning sampling over time ... but then when the pulse arrives.

Friends thanks for your attention, I remember I use labview 2010 ...... when sending their sujerencias take into account that detail.

0 Kudos
Message 1 of 3
(5,911 Views)

Duplicated post:

 

http://forums.ni.com/t5/Discusiones-sobre-Productos-NI/AYUDA-contador-digital/m-p/2470244#M23813

Guilherme Souza
Applications Engineering
National Instruments Brazil
0 Kudos
Message 2 of 3
(5,886 Views)

The duplicate post is in Spanish so I'll post here:

 

The 6008 has a single basic counter on it that can pretty much only do edge counting.  Luckily, it sounds like this is what you want to do.  It would look something like this:

 

SimpleCount6008.png

 

 

You would need to connect the signal to PFI 0.

 

 

Best Regards,

John Passiak