Hello CJ,
Whenever, I googled "dasylab vs. labview" for example I only got migration information, so my impression was it was possibly a legacy platform being retired, so a sincere thank you for helping me better understand where DasyLab fits in. As I get more acquainted with it, I definitely appreciate its niche, though you're right I miss LabVIEW.
Anyway, I am having some trouble with setting up "Action Modules," whenever I open the Options > Actions and hit "setup" the entire window just vanishes, but in searching the help files I came across the basic Key actions, which allowed me at least to use #'s 1-4 (if not the actual buttons corresponding to the ASCII values our device uses, say as in hyperterminal), to fully control it - and for my purposes I am happy with that. We are working with two devices actually. One is a custom device that continuously returns its status data and accepts commands as I described to change various settings. The second device, which I have not successfully hooked up yet, is a Mannix Digital Manometer (pressure sensor) that claims to have RS232 support, but that may only be with the company's proprietary cable and software. I would like to integrate that into DASYLab as well, as I will eventually need to compare and record in real time pressure sensing from that device with what our black box "thinks" it is doing for verification work.
Let me know if you know anything additional about that specific manometer, or mannix products, otherwise thanks again for the help thus far! Let me know also if I can provide any other information.
-WaddlingDuck
07-03-2007 11:36 AM