05-04-2010 03:50 AM
Dear Reader,
We are currently evaluating DasyLab 11 in combination with a IXXAT USB-to-CAN compact. Attached to this controller is the Elmo TRIO-WHI motion controller. The Composer software of Elmo is already opened and communicating over CAN. I try to log the communication between the controller and the adapter using the IXXAT-CAN Bus Logger. But when i try to start the logging i get the following error:
No channels (ports) available.
I configured the bit rate at a speed of 500kbps. Which should be fine, because it's the speed i configured the Elmo to use. I'd like to find out how to solve this problem. Thanks in advance.
05-06-2010 01:44 AM
Hello,
- you should use the Ixxat VCI-V3 API under DASYLab 11.x
- you should connect / open an Ixxat CAN interface with included CAN ports only with one software - use the logger OR DASYLab but not both togehter
MHa
05-07-2010 11:03 AM
05-09-2010 09:05 AM