DIAdem

cancel
Showing results for 
Search instead for 
Did you mean: 

Error -2584 occurred at DIAdem Report

Solved!
Go to solution

New to DIAdem,

I am running DIAdem 2010, LabVIEW 2010 and Windows 7. When I try to run the example Multipage Report.vi I get the following Error.

 

Error -2584 occurred at DIAdem Report

 

Possible reason(s):

LabVIEW:  DIAdem could not be started. You must have DIAdem 9.1 Service Pack 2 or later installed to use the DIAdem Report Express VI.

 

If I open the DIAdem Express vi the areas Select Layout and Target are greyed out.

 

I have download the LabVIEW-DIAdem Connectivity Toolkit but have "broken vi's"

 

 

0 Kudos
Message 1 of 3
(3,544 Views)

Any advise would be helpful.

Thanks in advance.

0 Kudos
Message 2 of 3
(3,543 Views)
Solution
Accepted by topic author patoh

Hi Patoh,

 

The error you are receiving could possibly be caused by the order in which your software was installed.

 

The usual installation order would be:

LabVIEW

Modules

Toolkits

Drivers

DIAdem

 

It is probably worth removing and reinstalling DIAdem on your system to see if this resolves your problem.

Post back to let me know how you get on.

 

Thanks,

 

 

 

 

Stephen C