Error 7 occurred at _createExplicitChildObject.vi DIAdem report express

I am using DIAdem Report express in LabVIEW.  I made a change in the file name and now it works most of the time but is generating an error.  Sometimes it doesn't work.

 

C:\Neuronetrix_Sync\Development\LabVIEW Test System\SC-1673\Logs\110091507\110091507 Frequency Response 5983823

This is the file path, it is constructed using string tools and then converted using string to path, then create folder then piped to the DIADEM report and Export Image function.

 

I get an error that cancels out the program the first time, then on subsequent runs it works just fine but still generates an error.

 

 

 

Error 7 occurred at _createExplicitChildObject.vi
Possible reason(s):
LabVIEW:  File not found. The file might have been moved or deleted, or the file path might be incorrectly formatted for the operating system. For example, use \ as path separators on Windows, : on Mac OS, and / on Linux. Verify that the path is correct using the command prompt or file explorer.

Error 7 occurred at _createExplicitChildObject.vi
Possible reason(s):
LabVIEW:  File not found. The file might have been moved or deleted, or the file path might be incorrectly formatted for the operating system. For example, use \ as path separators on Windows, : on Mac OS, and / on Linux. Verify that the path is correct using the command prompt or file explorer.

 

-Regards

eximo
_______________________________________________
UofL Bioengineering M.S.
Neuronetrix

"I had rather be right than be president" -Henry Clay
0 Kudos
Message 1 of 4
(3,626 Views)

Hi again eximo,

 

In your provided screenshot I can see no evidence that you are wiring any data to the dynamic data input terminal of the DIAdem Report express block.  Are you?  That would be an important omission and might cause the behavior you're seeing.

 

Brad Turpin

DIAdem Product Support Engineer

National Instruments

Message 2 of 4
(3,617 Views)

In the screen shot you can see I am using to DIAdem expresses.  When I was using just one express, and have everything wired up correctly, and everything works, i'm still getting the error.

-Regards

eximo
_______________________________________________
UofL Bioengineering M.S.
Neuronetrix

"I had rather be right than be president" -Henry Clay
0 Kudos
Message 3 of 4
(3,595 Views)

Hi eximo,

 

I only see 1 DIAdem Report express block in the screenshot, and it does not appear to have any data wired to it.  Would you be able to post the VI or email it to brad.turpin@ni.com?

 

Brad Turpin

DIAdem Product Support Engineer
National Instruments

0 Kudos
Message 4 of 4