I've run into a problem.

I have a measurement file that contains multiple channels of raw data.

 

I would like to plot this data as a waterfall on my report.

 

So first I load my N ammount of channels from the TDMS File into my workspace.

In order to do that I generate 2 caluclated channels using the Analysis paletter.

I do the following:

Generate a time channel as the X axis based on the number of steps.

Generate a numeric channel for the Y asix that corresponds to the N number of channles I have.

So these channels land at the end of my measurement group.

 

When I try to create a waterfall plot.. during the selection of the Z Matrix

the TimeGenerated and LinerarGenerated channels are allways selected.

I can't deselect them using CTRL+ Left Click Shift + Left Click...

How can I define my Z Matrix ... so that I ommit those channels.... I only want the RAW data to be selected.

 

Regards,

Maciej

 


0 Kudos
Message 1 of 3
(3,367 Views)

Attaching screenshot.

I don't know how to DESELECT the two channels from the Z matrix ...


0 Kudos
Message 2 of 3
(3,366 Views)

Dear Maciej,

 

I tried to reproduce your problem on DIAdem 2010 and I did not get the behavior you mentioned.

Could you please tell me what version of DIAdem are you using? A screenshot from "Help->About..." would be very helpful.

If it is possible please also attach the TDMS file with the data you want to process.

 

 

Regards,

0 Kudos
Message 3 of 3