09-01-2010 07:25 AM
Sorry for posting a wrong question Loading multiple files!!
As per my understanding only a standard Dat file can be compared with one single dat file.Because Eacg dat file will be containing its own values. So multiple files cannot be compared.
Am assuming dat files containing time(s) and acceleration values(g). G value for each file differs.
Thanku!!
Solved! Go to Solution.
09-02-2010 07:15 AM
Hi Rash.patel,
I'm still not sure I follow you. When you say "Dat" file, do you mean the DIAdem 8.x standard file with the *.dat header and usuall a *.r64 binary file or two that it references, or do you mean some other specific data file with the extension *.dat or do you just mean a generic data file?
DIAdem can certainly load multiple files into the Data Portal at the same time, so you must be referring to either a limitation of the "*.Dat" file you're talking about or correcting yourself that all the data you want to compare turns out to be in one "Dat" file.
Brad Turpin
DIAdem Product Support Engineer
National Instruments
09-02-2010 07:23 AM
Hi Rash.patel,
Sorry, I hadn't looked at your attachments-- rookie mistake. So now I know that you do mean an old "DIAdem DAT" file, though it has an *.r32 binary file instead of the *.r64 binary file I expected. Now worries, I can load that file just fine. So this thread is done, and I'll post the rest of my questions at your other thread.
Brad Turpin
DIAdem Product Support Engineer
National Instruments