09-17-2020 03:27 PM
Using Flexlogger, I have recorded a linear actuator position, using a digital optical encoder. The linear actuator travels from 0 inches to approx 2 inches. What is the easiest way to determine stroke time from 0 in to 98% of maximum recorded travel.
09-22-2020 04:51 PM
Hi Jacob,
Does your data set have a Time channel that you're using to graph the stroke vs. time, or is your stroke position channel a waveform channel?
Can you post a sample data set for us to look at?
Have you tried the "Y-Axis [%]" display in VIEW? That plus the cursor window and band cursors would give you a quick qualitative answer. If you want a programmatic, quantitative answer, I'll need to see your data.
Brad Turpin
Principal Technical Support Engineer