A Labview project is generataing TDMS files, on my computer the TDMS files are opended correctly in Excel.

While on other computers the users receives the following error: "Warning: The datatype of the channel 'NAME OF CHANNEL' is not supported by USI!"

This results in that when viewed in Excel, the channels contains 0 data. When I try to open the same file on my computer I get all the data.

0 Kudos
Message 1 of 3
(5,418 Views)
Solution
Accepted by topic author cdonc

Do you have the latest version of excel addins installed on the other machines?

 

http://zone.ni.com/devzone/cda/epd/p/id/2944

 

Which DIAdem/USI version are you using (DIAdem about box) and is NI Software installed on the other machines.

Message 2 of 3
(5,410 Views)

The issue was fixed by updating to DIAdem 2012