Where are MGI Panel Manager DQMH panels installed?

Using VIPM, I have installed this toolkit extension (LV2023, DQMH 7.0 installed), but the MGI panel templates don't show up when attempting to create a new DQMH module. How can I validate if the templates were actually installed, and is there a way I can do this manually?

_____________
Creator of the BundleMagic plugin for LabVIEW!
0 Kudos
Message 1 of 5
(334 Views)

I see the module templates when I install the latest version of the MGI Panel Manager with DQMH:

 

mgipanel.png

 

You can verify they are installed by ensuring the following files exist on your system:

[LabVIEW Data]\DQMH Module Templates\MetaData\Cloneable Panel.xml

[LabVIEW Data]\DQMH Module Templates\MetaData\Singleton Panel.xml

[LabVIEW Data]\DQMH Module Templates\Source\MGI\Cloneable Panel\*

[LabVIEW Data]\DQMH Module Templates\Source\MGI\Singleton Panel\*

 

If you don't know where the LabVIEW Data folder is on your system, you can find out at Tools > Options > Paths > Default Data Directory.

 

Note that there were some issues with the MGI Panels not having been updated to be compatible with recent DQMH releases. I remember hearing there were some plans in the works to update them, but I don't know if that's happened yet. You may want to run the DQMH Validate Module tool on MGI Panel modules you create.

 

Message 2 of 5
(321 Views)

What version of DQMH and MGI Panel Manager are you using?

 

I have:

DQMH v7.0.1.1316

MGI Panel Manager v1.0.1.4

 

I'm unable to see the Singleton and Cloneable Panel options when I try to create a new DQMH Module. I previously had this working but after getting a new PC and reinstalling LV 2020 and these packages I don't see this option anymore. Potentially something to do with MGI Panels not working with this version of DQMH as you mentioned?

0 Kudos
Message 3 of 5
(62 Views)

Did you verify the files are present on disk at the locations I described above? Did you verify that the Tools > Options location for [LabVIEW Data] matches those paths?

0 Kudos
Message 4 of 5
(58 Views)

I don't know why, but only once I post something do I almost always solve my problem. Almost always caused by my own stupidity. I had installed MGI Panel Manager via VIPM, but never actually installed MGI Panel Manager - DQMH Panels.

 

Thank you for your help! Checking those file locations made me realize nothing was there and that something was clearly missing.

0 Kudos
Message 5 of 5