12-27-2006 10:56 AM
12-27-2006 01:12 PM
Hi! Erik,
thanks for ur reply.
As I told you, 5 Mux IC connected Serially. For Selecting One IC I need 4 bits. That 4 bits make truth table and select INP0 - INP7. for selecting any input of those 5 IC I need 20 bits which are shifting one by one. If I talk abt only first MUX and 4 bits the pattern should be, 1000 - INP0, 1001-INP1......1111-INP7. like that. All five IC connected serially, we can select only one input at a time. If i want to select INP0, I have to shift 20 bits and pattern should be 1000 0000 0000 0000 0000. It will select only INP0 and gives the analog voltage of INP0. like that I have to measure INP0 - INP39.
second example, If I want to select INP8, than line 0 of second mux- so pattern should be 0000 1000 0000 0000 0000.
"1" shows Enable. for INP17, line 1 of MUX3, so pattern should be 0000 0000 1001 0000 0000.
For INP 39, line 7 of MUX 5, so pattern should be 0000 0000 0000 0000 1111.
This works automatically one by one and select each line and write the status of each line.
thanks
12-28-2006 09:44 AM