10-15-2007 10:12 AM
10-16-2007
04:04 PM
- last edited on
12-28-2024
02:13 PM
by
Content Cleaner
Hi Bill,
The Init_DA_Brds function actually uses VISA commands to communicate with your DAQ card. The install of NI-VXI 3.3.1 might have caused some type of corruption with NI-VISA or it installed an older version of NI-VISA (2.6.1 is installed with NI-VXI 3.3.1) that might not be compatible with the version of Traditional Ni-DAQ you are using. In Measurement and Automation (MAX) under the software tab, can you verify what version of NI-VISA is installed on the computer?
I would suggest doing the following:
1. Install the latest version of NI-VISA 4.1, found here.
2. If this doesn't fix the problem, I have a few more questions that might help us find a resolution. Did you uninstall NI-VXI 3.3.1? If you did, was it after or before you reinstalled the Traditional Ni-DAQ drivers? Also, what version of Traditional NI-DAQ are you using? What operating system are you using?
I hope this helps,
Paul C.
10-23-2007 09:05 AM
Thanks, for some reason I didn't notice that you responded to this. I actually posted another thread on this topic.
I'm running Labwindows/CVI 8.1.1 with NIDAQ 7.4.4 (latest version I think) and NI-VXI 3.3.1 and NI-VISA 4.1.
On my desktop PC which only has 1 PCI segment, I can install the hardware and software and everything works. Then I install NI-VXI and it stops working. However on the desktop PC I could reinstall NIDAQ and get it to start working again. But on the industrial PC, that procedure doesn't work. The only real difference between the two is that the industrial computer has 5 PCI bridges and a boat-load of peripherals.
I've removed everything from the system and tried every slot and just can't get anywhere.
Thanks,
Bill Peters
10-24-2007 08:56 AM
Hi,
I've tried a bunch of combinations of installed orders. For instance I installed VXI 3.3.1 first hoping to over write It's VISA stuff. Then reinstall VISA 4.1. I even removed NI-DAQmx and reinstalled NI-DAQ 7.4.4. No combination works. But as soon as I remove VXI it starts to work (I don't even have to reboot).
I do have a question about MAX. It shows an unidentified PXI system, and several of my devices show up under that catagory (including the DAC). Why is that there? I thought maybe it might be a hint. I can't get rid of it. Maybe one of my PCI bridges makes it think I have PXI?
Anyway this is my third week trying to get this to work and beleive me, I am out of ideas.
Thanks,
Bill Peters
BAE SYSTEMS
10-24-2007 09:42 AM
10-25-2007 08:16 PM