Digital I/O

cancel
Showing results for 
Search instead for 
Did you mean: 

changing the IRQ manually for NI-PCI6503 on windows 2000

Hello

 

I need yours help on this matter

 

I have installed a NI PCI 6503 board to my PC before installing the driver for the board the board receive the IRQ that I manually assigned in the BIOS (IRQ3)

 

My problem is that after installing the driver (NIDAQ) the board receive and IRQ 21

 

How can I change it back to IRQ 3?

 

Apposite yours help

Hen Gershengold    
0 Kudos
Message 1 of 8
(4,066 Views)
Hi,
 
Have you tried changing it again through the BIOS after installing the driver?
 
Also, is there any specific reason why you are trying to change the IRQ level? Is the card not functioning properly.
 
 
Abhinav T.
Applications Engineering
National Instruments India

LabVIEW Introduction Course - Six Hours
Getting Started with NI-DAQmx
Measurement Fundamentals
0 Kudos
Message 2 of 8
(4,050 Views)
Dear Abhinav
 
Thank you for your response.
 
Yes I tried to change it again after the installation the results are
The IRQ for the PCI slot is 3 but the IRQ of the board is 21
 
The reason that I want do change the IRQ is because I have a delay of about 100mS in every read for the board
 
This make it difficult for me to measure correctly
 
On a different PC, duplicate test station  with the same board on IRQ 9 all measures are correct
 
Thanks for the help
Hen
0 Kudos
Message 3 of 8
(4,041 Views)
Hen,
 
Have you tried just moving the card to a new slot? This should change the IRQ level.
 
 
Abhinav T.
Applications Engineering
National Instruments India

LabVIEW Introduction Course - Six Hours
Getting Started with NI-DAQmx
Measurement Fundamentals
0 Kudos
Message 4 of 8
(4,024 Views)
Abhinav
 
Yes I have changed the slot but the IRQ changes for 21 to 19 this did not helped
 
Hen
0 Kudos
Message 5 of 8
(4,020 Views)

Hen,

What is the difference between the 2 computers? Are they using 2 different boards, BIOS, OS?

I find it very strange that the IRQ level is realted to your acquisition rate. Is the only difference betweent he 2 computers the IRQ level?

 

Abhinav T.
Applications Engineering
National Instruments India

LabVIEW Introduction Course - Six Hours
Getting Started with NI-DAQmx
Measurement Fundamentals
0 Kudos
Message 6 of 8
(4,014 Views)
Abhinav,
 
Yes both computers are the same the only different is the IRQ level
how can I change the IRQ level
I think that it will be the same
 
Hen
0 Kudos
Message 7 of 8
(4,012 Views)
Hen,
 
I would like to take this service request off the forums for a while, resolve this in a phone support call instead and then post the final resolution. Can you please create a new service request here: www.ni.com/ask and ask to speak with an Applications Engineer?
Abhinav T.
Applications Engineering
National Instruments India

LabVIEW Introduction Course - Six Hours
Getting Started with NI-DAQmx
Measurement Fundamentals
0 Kudos
Message 8 of 8
(3,993 Views)