Dynamic Signal Acquisition

cancel
Showing results for 
Search instead for 
Did you mean: 

error with property nodes and svx_DAQmx Popup for DSA.vi

Some example vi of the sound and vibration toolset 3.1 use property nodes with an undefined class (e.g. svx_DAQmx Popup for DSA.vi). I use Labview 7.1 and NI-DAQmx. Could it be that the vi uses classes from traditional NI-DAQ?
0 Kudos
Message 1 of 4
(7,507 Views)
Which example gives the error? Could you post a screenshot of the error? What version of DAQmx are you using? Was this example ever working on your machine, or did it just start failing after an upgrade of LV? DAQmx? SVT?

Doug
Sound and Vibration Applications
National Instruments
Doug
Enthusiast for LabVIEW, DAQmx, and Sound and Vibration
0 Kudos
Message 2 of 4
(7,502 Views)
The error occurs in:
C:\Programme\National Instruments\LabVIEW 7.1\examples\Sound and Vibration\Utility\Daq\DAQmx\svx_Get DAQmx Info.vi
C:\Programme\National Instruments\LabVIEW 7.1\examples\Sound and Vibration\Utility\Daq\DAQmx\svx_DAQmx Popup for DSA.vi
see also attached screen shot.
It is a new installation on a PXI-system, WinXP, LabView 7.1, SVT 3.1, NI-DAQ 7.4 (only DAQmx driver installed). The examples had not been tested before.
0 Kudos
Message 3 of 4
(7,497 Views)
I suspect that the Sound and Vibration Toolkit was installed before DAQmx. I recommend that you uninstall SVT and then reinstall SVT (now that DAQmx is already installed).

Doug Bendele
Sound and Vibration Applications
National Instruments
Doug
Enthusiast for LabVIEW, DAQmx, and Sound and Vibration
0 Kudos
Message 4 of 4
(7,492 Views)