Niel,
The FP Open.vi provides a FP Refnum in the form of a data cluster. The cluster contains two elements; a server refnum and a tag refnum. Coming out of the FP Open, only the server refnum has a value, the tag refnum is created when the FP Create Tag.vi is processed. Thus all FP refnums in a process have the same server refnum but different tag refnums. The FP Close.vi uses the server refnum to close the server and ignores the tag refnum so it does not matter which particular refnum was used to close the server. The thing to be careful of is if you close on refnum, you close all refnums. At this point, any reads/writes/advises will result in error 32804 (Invalid IA handle specified).
Also, please swamp this forum with questions. I am in the process of reviewin
g the documentation and examples we provide and having a beginner asking questions that do not appear to be covered in our materials gives me an idea of what we are missing. I would ask that you upgrade to FieldPoint Explorer 2.0.4 and use the online help for LabVIEW since that has had some of my modifications added to it (program flow outlines, vi descriptions & use cases).
Regards, Aaron
LabVIEW Champion, CLA, CPI