How to purge com in VISA 2.6/2.61?
How to purge com in VISA 2.6/2.61?
km9394
Member
10-16-2003
03:10 AM
Options
Mark as New
Bookmark
Subscribe
Mute
Subscribe to RSS Feed
Permalink
Print
Report to a Moderator
I need to do code migration of a program involve serial actions, from Visual C++ to LabWindow/CVI.
However, I don't know how to purge com. There is no equivalent function to "CommPurge". Is there any method to purge com in CVI?
0
Kudos
Message
1
of 2
(3,259 Views)
Reply
Re: How to purge com in VISA 2.6/2.61?
Dan_Mondrik
Active Participant
10-17-2003
10:56 AM
Options
Mark as New
Bookmark
Subscribe
Mute
Subscribe to RSS Feed
Permalink
Print
Report to a Moderator
Just make the following call:
viFlush (vi,VI_IO_IN_BUF_DISCARD|VI_IO_OUT_BUF_DISCARD);