02-24-2011 12:31 PM
I am having problems with recognizing the subject card in my computer. The computer's OS is Windows 95 ver. 4.00.950 C. The driver loaded is NIDAQ693. I am replacing a defective PC-DIO-96/PnP, PN: 183549E-01. I have noticed that the -01 has items F521, U16, and W2 not installed. While the -02 has those items installed and U8 and U12 are uninstalled. Concerns I have is if these two cards are compatable and is the -02 as discribed PnP? MAX 2.2 also does not find the -02 card in the computer. Should I upgrade the OS and if so is Windows 95 with USB Support good or Windows 98? I am also using LabView 5.0 with this system. Any assistance you can provide is greatly appreciated.
02-28-2011
11:04 AM
- last edited on
06-24-2024
12:01 PM
by
Content Cleaner
Hello Terry,
Since your system appears considerably old and antiquated, my suggestion is to upgrade to a new computer with at least a Windows XP SP3 operating system. Hardware becomes unreliable over the course of time. Since your system is over a decade old, your system may become subject to more issues in the near future. Moreover, we have since stopped supporting NI-DAQ and recommend customers to upgrade to NI-DAQmx. If you do need additional support, please call National Instruments support and an applications engineer would be happy to further assist you in this matter. Below are a few links regarding the upgrade process:
Transition from Traditional NI-DAQ to NI-DAQmx in LabVIEW
How to Upgrade or Revert a VI to a Different Version of LabVIEW
https://knowledge.ni.com/KnowledgeArticleDetails?id=kA03q000000YSO4CAO&l=en-US