LabVIEW Communications System Design Suite

cancel
Showing results for 
Search instead for 
Did you mean: 

[USRP-RIO] Error -367000 in modified streaming example

Hi,

 

we are using the following setup:

 

  • A USRP-RIO is connected via PCI card to a desktop PC (transmitter)
  • Another USRP-RIO is connected via PCI card to another desktop PC (receiver)
  • A modified version of the stock streaming example is used to transmit and receive.
  • The modifications are limited to waveform generation and display, i.e. 2 independent Tx channels and 2 independetnt Rx channels are employed
  • LVC version 1.0.0.50009

Turning the transmitter on and off, every once in a while, this message would occur after pressing the "STOP" button. Between the different runs, I have been actually only changing some settings in the GUI. The behaviour was not reproducible in a deterministic way.

 

random_error.png

 

By now, the problem does not occur anymore. Not sure what was the actual solution.

 

Nicola

0 Kudos
Message 1 of 2
(5,639 Views)

Hi Nikola,

 

since you do not know, which settings produced the issue, I can only guess what could have been the cause: The error usually indicates a trigger timeout. So if you use a trigger line but no trigger is received over a specified time, the error message is seen.

 

Best regards,

Melanie

Best regards,
Melanie Eisfeld
Senior Applications Engineer, National Instruments Germany
Certified LabVIEW Developer
Certified TestStand Architect
0 Kudos
Message 2 of 2
(5,622 Views)