You can find the TSA Welch.vi under

 

Signal Processing | Time Series Analysis  | Correlation and Spectral Analysis.

 

It comes with the "Full Developers Suite".

 

0 Kudos
Message 11 of 17
(4,937 Views)

us09 wrote:

It comes with the "Full Developers Suite".


Well, I have LabVIEW professional and don't have it.

 

I believe these tools are part of the NI LabVIEW Advanced Signal Processing Toolkit which costs extra. 😞

0 Kudos
Message 12 of 17
(4,934 Views)

us09 wrote:

It comes with the "Full Developers Suite".


OK, you are mixing terms here, don't use "Full" in this context. 😉

 

There is "Base", "Full", "Professional", and "NI Developer Suite". You must have the last one. (details)

0 Kudos
Message 13 of 17
(4,931 Views)
Yep. I have the last one.
0 Kudos
Message 14 of 17
(4,920 Views)
It is part of the Advanced Signal Processing toolkit. 
Randall Pursley
0 Kudos
Message 15 of 17
(4,908 Views)
Solution
Accepted by topic author us09
Back to your original question.  It appears that the Mathscript interface is not optimized enough to match performing the same function outside Mathscript.  But, I'm sure in the next version of LabVIEW, this will be improved upon, but I'm guessing will never quite reach the same performance as calling the function directly outside of Mathscript.
Randall Pursley
0 Kudos
Message 16 of 17
(4,902 Views)

Thanks a lot for the information. I know that interfaces can be quite a

problem for data exchange. So I am looking forward to the next version

of MathScript Smiley Happy.

 