LabVIEW

cancel
Showing results for 
Search instead for 
Did you mean: 

2 questions

Hi All,

2 completely different LabVIEW questions but they pertain to the same
app.

1. How can I progrmatically init a table to it's default value? I
can't seem to find it via the property node.

2. Is there a way to adjust the brightness of the display for the
media player? I am using it via an ActiveX container and would like
to have a front panel control to adjust this.

Thanks,

Greg
0 Kudos
Message 1 of 3
(2,624 Views)
You can use an invoke node to set a control or indicator to its default value.
1. Right-click on the control or indicator and select Create >> Invoke Node.
2. Right-click on the Invoke Node and goto Methods >> Reinit to Dflt.
3. Put this invoke node wherever you want to restore the default.
0 Kudos
Message 2 of 3
(2,624 Views)
Eureka! That did the job exactly. I was too fixated on doing it via
the property node.

Cheers,

Gc.

Al S wrote in message news:<506500000005000000E5130100-1042324653000@exchange.ni.com>...
> You can use an invoke node to set a control or indicator to its
> default value.
> 1. Right-click on the control or indicator and select Create >> Invoke
> Node.
> 2. Right-click on the Invoke Node and goto Methods >> Reinit to Dflt.
> 3. Put this invoke node wherever you want to restore the default.
0 Kudos
Message 3 of 3