3D Graphs cause LV 2009 to CRASH

Solved!
Go to solution

Hi all,

 

The placing of any of the new 3D graph controls on the front panel causes LV 2009 to Crash!

 

Please advise.

 

Battler.

0 Kudos
Message 1 of 10
(3,760 Views)
Can you elaborate a little bit?
0 Kudos
Message 2 of 10
(3,754 Views)

When I drop any of the new 3D graphs onto the front panel (whether it's a new or existing VI) LV 2009 loads a number of subVIs (presumably required for the 3D graph functionality) and then LV simply close and disappears (i.e. crashes).

 

I have installed the latest LV 2009 "f2" patch.

0 Kudos
Message 3 of 10
(3,748 Views)
Does anyone else have the same problem and/or know how to resolve?
0 Kudos
Message 4 of 10
(3,725 Views)
Solution
Accepted by battler.

Hi battler.,

 

Does this happen for all 3D Graphs or just specific ones? I have found a CAR that seems to be similar to the issue you are seeing, but I am looking into that further and will post when I have more information. In the mean time, you may want to try a LabVIEW Repair.

 

Thank you for choosing National Instruments.

 

Aaron Pena

National Instruments

Applications Engineer

http://www.ni.com/support

0 Kudos
Message 5 of 10
(3,714 Views)

Hi,

 

It happens for all 3D graphs.

 

Please get back to me as I want to use them.

 

Cheers,

 

Battler.

0 Kudos
Message 6 of 10
(3,698 Views)

Hi battler.,

 

Unfortunately, that CAR was closed because it was not reproduceable. My recommendation at this time would be to do a LabVIEW Repair. To do this, go to Control Panel»Add or Remove Programs»National Instruments Software»Change/Remove»LabVIEW 2009»Repair. You may need your installation discs for this operation.

 

Thank you for choosing National Instruments.

 

Aaron Pena

National Instruments

Applications Engineer

http://www.ni.com/support

0 Kudos
Message 7 of 10
(3,666 Views)

Thankfully the Repair worked.

 

Cheers,

 

Battler.

0 Kudos
Message 8 of 10
(3,647 Views)

Hi battler.,

 

I'm glad that the Repair solved the issue!

 

Thank you for choosing National Instruments.

 

Aaron Pena

National Instruments

Applications Engineer

http://www.ni.com/support

0 Kudos
Message 9 of 10
(3,630 Views)

 


Thankfully the Repair worked.

 

 

Thanks for updating

0 Kudos
Message 10 of 10
(3,621 Views)