LabVIEW

cancel
Showing results for 
Search instead for 
Did you mean: 

Application Builder with DAQmx vis

Solved!
Go to solution

Do you mean 'DAQmx Create Virtual Channel' ?

I never ran into such a situation. Indeed it's odd and seems to indicate a defective driver installation.

Paolo
-------------------
LV 7.1, 2011, 2017, 2019, 2021
0 Kudos
Message 11 of 15
(1,181 Views)

Yes, I'm just trying to download the same drivers that I have on my developer PC, how do I delete the first set of drivers I installed?

 

Thank you

0 Kudos
Message 12 of 15
(1,177 Views)

Hi Cran,

 

uninstall them…

Best regards,
GerdW


using LV2016/2019/2021 on Win10/11+cRIO, TestStand2016/2019
0 Kudos
Message 13 of 15
(1,172 Views)

In the Control Panel as other applications. Search National Instruments Software.

Try uninstalling everything by NI and starting from scratch.

Paolo
-------------------
LV 7.1, 2011, 2017, 2019, 2021
0 Kudos
Message 14 of 15
(1,170 Views)
Solution
Accepted by Cran91

Thanks all, it now works once I had the exact same drivers on the target PC as shown in DAQmx under Software as the developer PC

0 Kudos
Message 15 of 15
(1,139 Views)