Application Error, Computer Freeze, NIPALK, PXIPreallocatedMemBlockSize

Hello,

i have a problem with one of my applications on a second computer. After an unknown time the

computer freeze an i have an error message on screen (in german, translated like this):

 

"The command 0x6d1189d7 reference to memory 0x00000000. The command could

not be executed in memory".

 

The Windows Event has logged the following:

 

Protokollname: System
Source:        NIPALK

Beschreibung:
[NI-VISA] [PXI]  Warning: 'PXIPreallocatedMemBlockSize' key not found
Ereignis-XML:
<Event xmlns="http://schemas.microsoft.com/win/2004/08/events/event">
  <System>
    <Provider Name="NIPALK" />
    <EventID Qualifiers="36608">8192</EventID>
    <Level>3</Level>
    <Task>0</Task>
    <Keywords>0x80000000000000</Keywords>
    <TimeCreated SystemTime="2014-10-01T07:13:52.782273800Z" />
    <EventRecordID>12548</EventRecordID>
    <Channel>System</Channel>
    <Computer>THY139</Computer>
    <Security />
  </System>
  <EventData>
    <Data>
    </Data>
    <Data>[NI-VISA] [PXI]  Warning: 'PXIPreallocatedMemBlockSize' key not found</Data>
    <Binary>0000000002003000000000000020008F000000000000000000000000000000000000000000000000</Binary>
  </EventData>
</Event>

 

What i don't understand is, that the same software is running on an other comupter since 2 years without

that message.

 

Computer 1 (working fine)

Windows 7 x32, all updates

LabVIEW Run-Time 2012 SP1 f5

NI-VISA 5.4.1

DAQmx 9.8 with NI-USB 6225 DAQ Device

 

Computer 2 (sometimes freeze)

Windows 7 x64, all updates

LabVIEW Run-Time 2012 SP1 f5

NI-VISA 5.4.1

DAQmx 9.8 with NI-PCI 6225 DAQ Device

 

Does someone have an idea?

 

0 Kudos
Message 1 of 3
(3,675 Views)

hi,

 

how do you configure your divice? With VISA ore with DAQmx?

In case of NI-VISA it would be possible to fix that with version 14.0.

Did you tried this allready?

 

 

NI-VISA 14.0 - National Instruments
http://www.ni.com/download/ni-visa-14.0/4722/en/

 

 

regards

hofstk

0 Kudos
Message 2 of 3
(3,636 Views)

I use MAX for the configuration and configured that are two SCB-68A connected to the card.

But due to a complete new installation of LabVIEW Run-Time, VISA Run-TIme and DAQmx

i forgot to configure that again.

 

I have done that now and will post a followup if that was the solution.