a.winslow,
I was able to duplicate the problem and altenbach's solution. What happens when you try altenbach's solution? This is currently a known bug in LabIVEW.
 
Chris C
 
0 Kudos
Message 21 of 25
(1,270 Views)

"This is currently a known bug in LabIVEW."

Could you please share the CAR# for this bug?

Ben

Retired Senior Automation Systems Architect with Data Science Automation LabVIEW Champion Knight of NI and Prepper LinkedIn Profile YouTube Channel
0 Kudos
Message 22 of 25
(1,265 Views)

A.winslow,

This is just a wild guess.

could you right-click on ALL of the constants on the diagram (that were created by right-clicking and doing a creat constant) and observe were the labels show up.

I have seen more than one case where the labels show up in extreme left field. (I would report this as a bug but I have to get SOME work done). Smiley Wink

Ben

Retired Senior Automation Systems Architect with Data Science Automation LabVIEW Champion Knight of NI and Prepper LinkedIn Profile YouTube Channel
0 Kudos
Message 23 of 25
(1,256 Views)

Hey Ben,

Your absolutely right.... the CAR number is 3T27J77R. Sorry about that.

 

Chris C

0 Kudos
Message 24 of 25
(1,231 Views)

This was reported to R&D (# 3T27J77R) for further investigation.

This notification posted for tracking purposes.

Chris C

0 Kudos
Message 25 of 25