LabVIEW

cancel
Showing results for 
Search instead for 
Did you mean: 

Cannot create controls/constants/indicators from XML parser

Solved!
Go to solution

Is there any reason I cannot create (by right clicking) a control/constant/indicator of a XML ref from the XML parser function? I need to make subvi's to build/read xml files, and that is really impossible without that ability.

 

Labview 2012 f3

Message 1 of 4
(2,707 Views)
Solution
Accepted by thutch79

This bug has already been reported (CAR 357092), and is scheduled to be fixed in the next service pack release. For now, here's a workaround:

 

1. Create a reference indicator from Functions » Programming » File I/O » XML » XML Parser » New.vi.
2. Right click on the new "DOM Document Out" indicator terminal and select Create > Control (or Indicator).

3. Right click on the new control/indicator and choose Select XML Parser Class. Then, you can select whatever class you need.

Message 2 of 4
(2,703 Views)

Thanks. I found an old reference to this problem in Labview for Linux, but it indicated it was fixed in 2011. I didn't see anything associated with 2012. 

0 Kudos
Message 3 of 4
(2,699 Views)

@thutch79 wrote:

Thanks. I found an old reference to this problem in Labview for Linux, but it indicated it was fixed in 2011. I didn't see anything associated with 2012. 


I believe the problem occurred several releases ago...it was fixed in 2011, but unfixed in 2012. 😉

0 Kudos
Message 4 of 4
(2,697 Views)