Hello,

 

I am have a thermocouple that needs a scale applied to it. So I created a virtual channel and applied my scale. Now I need to connect it to Read.vi. However, I already have "MyTemperatureTask" connected to read.vi. How to I put two different connections into read.vi? See attached image.

 

Thank you,

 

Natalie

0 Kudos
Message 1 of 3
(2,455 Views)

Hi Natalie,

 

use one DAQmxRead per DAQmx task.

(You might put all channels into just one DAQmx task, when your device allows it.)

You know this great document from NI?

 

Are you sure about using a stacked sequence with 10 frames?

Best regards,
GerdW


using LV2016/2019/2021 on Win10/11+cRIO, TestStand2016/2019
0 Kudos
Message 2 of 3
(2,378 Views)
Solution
Accepted by topic author nsmit106

The solution was to put an equation in manually rather than do the scale. I used Formula Node for the equations.