DAQ 7 and Lab view 6.02

The NI DAQ seems to have some nice features and we should definitly like to explore it and probably use it in our current LV 6.02 project.
But I do not see chances to upgrade to LV 7.
Can I use the multithreading of NI DAQ 7 also in LV 6.02?
Gabi
7.1 -- 2013
CLA
0 Kudos
Message 1 of 2
(2,589 Views)
The new DAQmx API can only be used in LabVIEW 7. For earlier version of LabVIEW, NI-DAQ 7 uses what NI calls Traditional DAQ, which is basically NI-DAQ 6.9.3.

So if you can't upgrade LabVIEW to 7, there's not much use in using DAQ 7.

Ed


Ed Dickens - Certified LabVIEW Architect
Lockheed Martin Space
Using the Abort button to stop your VI is like using a tree to stop your car. It works, but there may be consequences.