LabVIEW

cancel
Showing results for 
Search instead for 
Did you mean: 

DAQ and Coriolis Flow Meter

Hey,

 

Can someone help me... I need to hook up a Coriolis Flow Meter with the Transmitter IFT9701 to the NI-DAQ - FP1000 but I can't find the wiring diagram.

 

There are just three wires coming out of the transmitter (red, black and plain) and gives an output of 19.8 volts on a multimeter.

 

Also, If you have any VIs or know where they are to find the flow rate measured my the flow meter, kindly send me the link or the file to saravarad@gmail.com

 

Thanks in advance!!

 

Have a great day!

 

Regards,

 

Saranathan

0 Kudos
Message 1 of 3
(3,317 Views)

There are just three wires coming out of the transmitter (red, black and plain)

-- What does "plain" mean - do you mean uninsulated?

 

If so, I would guess a 4-20 mA output. 

 

 

and gives an output of 19.8 volts on a multimeter.

 

That's meaningless unless you tell us if and how it's powered, and what resistor you used to measure.

 

Did you look up the specs?

It is indeed a 4-20 mA output. 

Steve Bird
Culverson Software - Elegant software that is a pleasure to use.
Culverson.com


LinkedIn

Blog for (mostly LabVIEW) programmers: Tips And Tricks

0 Kudos
Message 2 of 3
(3,304 Views)

FYI, you can find the datasheet at:

 

http://www.emersonprocess.com/Micromotion/products/transmitters-IFT9701.html

 

 

-Matt Bradley

************ kudos always appreciated, but only when deserved **************************




0 Kudos
Message 3 of 3
(3,294 Views)