07-21-2010 02:08 PM
I have a pc that was refreshed. They installed LabView 7.1, 8.0, 8.2 and 8.2.1 back on the new pc. After updating the drivers for a new USB-6525 the DAQ assistant and the DAQ mx are no longer there and any VI that I used before that had them no longer work. I do get a message that is requires an add-on. Has anyone else had this problem or know what I need to do to fix it? When I try to load an example of anything using the mx I get the warning see attached photo.
Solved! Go to Solution.
07-21-2010 04:10 PM
If your code used DAQmx and you did not reinstall it, then you need to install DAQmx. You can get it from the Device Drivers CD, or you can download it from the NI site. Be sure to look at the compatibility page to make sure you get the correct version based on the multiple versions of LabVIEW that you have.
07-23-2010 09:17 AM
That took care of the problem thanks for the help