Could you post a MAX technical report of your system? This will give us a general idea of how your system is configured and what kind of NI software is installed. Below is a guide to generate one:

 

KB 3ST8N46P: Documenting Measurement & Automation Explorer (MAX) Configuration Information

Steven K.
National Instruments
Software Engineer
0 Kudos
Message 11 of 13
(574 Views)

Hello FredATI, hope you are doing great.

 

Can you please verify you included the DAQmx runtime engine in the build.

 

Seems to me that it is working on the XP machine because you have the runtime engine in that computer  and not in the Windows 7 machine.

 

Regards, 

 

Luis A.

National Instruments.

Applications Engineer.

 

 

0 Kudos
Message 12 of 13
(558 Views)
Solution
Accepted by FredATI

I found the problem!!

 

The .exe was located on the shared server.  When I move the .exe (and .ini and .alias) to the local C:/ drive, it works!

 

This issue is for Windows 7 only.  The .exe can run off the server in Windows XP.

 

thanks to everybody for the help

 

Fred

 

Message 13 of 13
(543 Views)