12-14-2011 11:10 AM
Could you post a MAX technical report of your system? This will give us a general idea of how your system is configured and what kind of NI software is installed. Below is a guide to generate one:
KB 3ST8N46P: Documenting Measurement & Automation Explorer (MAX) Configuration Information
12-14-2011 11:25 AM
Hello FredATI, hope you are doing great.
Can you please verify you included the DAQmx runtime engine in the build.
Seems to me that it is working on the XP machine because you have the runtime engine in that computer and not in the Windows 7 machine.
Regards,
Luis A.
National Instruments.
Applications Engineer.
12-14-2011 12:23 PM - edited 12-14-2011 12:26 PM
I found the problem!!
The .exe was located on the shared server. When I move the .exe (and .ini and .alias) to the local C:/ drive, it works!
This issue is for Windows 7 only. The .exe can run off the server in Windows XP.
thanks to everybody for the help
Fred