Error -200220 occurred at DAQ Assistant

Hello all,
 
For the past 3 months I've had a test running which collects the voltage level of a source every hour and then plots it.  The test has completed but in order to be more efficient we have to take the voltage levels of two more sources.  The sources are a blue, red, and green LED board system.
 
Message received:
Error -200220 occurred at DAQ assistant
Possible reason(s):
Device identifier is invalid
Device Specified: Dev1
 
Through Measurement and Automation the NI DAQmx Device PCI-6034E "Dev2" works perfectly fine along all channels on the BNC-2110
However the Traditional NI-DAQ(Legacy) PCI-6034E (Device1) freezes up when I try and open the test panels.
 
Any easy way going about fixing this?
 
Thanks,
 
0 Kudos
Message 1 of 2
(2,773 Views)

Problem fixed.  On Dev1 the board wasn't recognized...switched it to Dev2 and now it recognizes the PCI-6034E.

 

 

0 Kudos
Message 2 of 2