12-09-2018 08:18 PM
That's a picture of your code. But it doesn't describe the delay you are talking about.
And what is the point of the amplitudes and levels subVI's?
12-09-2018 08:35 PM
Sorry, I do not understand your question
12-09-2018 08:40 PM
Sorry, I don't understand what you are trying to do in your code.
12-09-2018 08:43 PM
@JoseGo94 wrote:
I managed to acquire the amount of data required (10 samples / second). Only that there is a delay between the physical measurements and the data that I acquire. For example, my LVDT changes 1.1 in to 0.5 in, while the numerical value of labview is still 1.1 in.
Since you used Express VIs we can't see what your settings are from your pictures.
My guess is that you are acquiring data and then your analysis in your processing loop is adding a delay between when the data is acquired and when it is displayed. Whatever processing that happens between acquisition and display is unavoidable.
Cheers
--------, Unofficial Forum Rules and Guidelines ,--------
'--- >The shortest distance between two nodes is a straight wire> ---'