LabVIEW

cancel
Showing results for 
Search instead for 
Did you mean: 

FPGA Analog Output Problem

I wrote code for PXI-7831R(FPGA) Analog Output.
When i excute under Labview environment, this code is no problem.
But, when i make excutable file, FPGA Card don't output minus voltage. (puls voltage is no problem)
 
What's problem ??
 
0 Kudos
Message 1 of 4
(3,700 Views)

Hi GoodTime,

Can you post your code?

Charlie Rodway | Principal Software Engineer | Certified TestStand Architect (CTA)

Computer Controlled Solutions Ltd | NI Silver Alliance Partner | GDevCon#1 Sponsor

Message 2 of 4
(3,693 Views)
Thank for your reply, SandmanUK.
 
i found solution for the problem last night.
 
i connected numerical result (double type) directly to FPGA Analog Output.
 
So, i inserted  numeric conversion (To word integer), then the problem disappear.
 
i think  auto type-conversion-mechanism of LV have internal Bug.
--- between "LV Environment" and  "Start Up Excutable"
 
 
 
 
 
 
0 Kudos
Message 3 of 4
(3,686 Views)

Hi,

I see. I don't think that the FPGA supports double types.

Charlie Rodway | Principal Software Engineer | Certified TestStand Architect (CTA)

Computer Controlled Solutions Ltd | NI Silver Alliance Partner | GDevCon#1 Sponsor

0 Kudos
Message 4 of 4
(3,680 Views)